High Frequency
High Frequency operating at 3–30 MHz.
-
Product
Coaxial Plug-in Switch Card
1260-152/172
Switch Card
The Astronics 1260-152/172 is a high- frequency coaxial switch card for use in either the Adapt-a-Switch® 1260-100, VXI carrier, or the 1256, GPIB/RS-232 Switching Mainframe.
-
Product
Signal Analysis
Super-Resolution Spectrum
-
Super-resolution Spectrum is used for spectral signal analysis with high frequency resolution. The program is used in diagnostics and monitoring systems of buildings and for analyzing non-stationary signals. The Software enables solving the following tasks:
-
Product
Differential Probe
DP-100
-
*This is the first detachable design (patent for 15 years)*High frequency, big power using. Max. Measuring is 7000Vp-p.I*t is capable for any brand of digital and analog oscilloscopes.*Additional AC Adaptor.*16MΩ high input impedance.
-
Product
Digital Hay Moisture Meter
LD-LHMM-A10
-
Digital hay moisture meterLD-LHMM-A10is a digital device used for determination of moisture content in the various types of hay samples from agricultural waste. High frequency principle of more than 10 MHz is used for moisture measurement. It gives high precision test results due to wide measuring range. Quick moisture determination is achieved due to its compact and light weight design. Ideally used for moisture measurement in samples like sugarcane waste, corn stalks, wheat straw, bamboo, tobacco leaf, etc.
-
Product
Electrodynamic Vibration Generator System
LVD-100KG
-
• Vibration table size: 500*500mm (Other size can be designed) • Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable) • Maximum test load Capacity: 100kg • Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz. • Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set real standard arbitrarily to sweep frequency back and forth • Programmable Function (1~600Hz): It can set each segment in 15 segments arbitrarily (frequency/amplitude/time/acceleration), and it can be recycled • Frequency doubling function (1~600Hz): 15 segments multiplied-increase: 1)Low to high frequency 2)High to low frequency 3)Low to high and then to low frequency, it can be recycled • Logarithmic function (1~600Hz), 3 modes of logarithm/can be recycled: 1)Lower to upper frequency 2)Upper to lower frequency 3)Lower to upper and then to lower frequency • Measuring instrument: To display amplitude, acceleration speed and the maximum acceleration speed.
-
Product
Basic Unit - Medical Equipment Functional Test Module System
GS-X
-
The GS-X Testing System consists of a Basic Unit and various plug-in test modules which the user can purchase as required. The range of functions of these Module-Box is being continuously expanded, and presently includes functions for testing the following devices: - Infusion pumps, Cardiac pacemakers, Defibrillators, High-frequency Surgical equipment, electrical safety ECG Simulation, Equipment for electro-stimulation.
-
Product
DC-DC Switching Converters
-
ST’s monolithic DC-DC switching regulators offer input-voltage capability up to 61 V, buck converters able to deliver output currents up to 6 A, and high switching frequency up to 2.3MHz.
-
Product
Miniature Rotating Optical Choppers
350C and 350CD
-
Model 350 is a high stability variable frequency optical chopper. The basic system consists of a control unit and a chopping head. It is supplied with four chemically blacked 30 mm diameter discs. These discs are of 2, 4, 10 and 40 slots and allow operation over the frequency range 10 Hz to 10 kHz.
-
Product
6 Channel Function Generator / Flow Simulator
DP-cPCI-2601
-
DP-cPCI-2601 is a 6 Channel 2MS/s Waveform Generator with high frequency performance, versatility and compact size in an economical cPCI bus format. Signal output in the range of 10 mHz to 5 KHz with 14 bit vertical resolution makes this single slot, 6U-sized cPCI card a powerful solution to meet most demanding test stimulus.DP-cPCI-2601 uses Direct Digital Synthesis (DDS) technique to generate stable and accurate output waveforms down to 0.01 Hz resolution. DP-cPCI-2601 offers Sine, Square, Ramp, Triangle, Pulse as built-in wave shapes and user defined arbitrary waveform.DP-cPCI-2601 can frequency sweep any of its function outputs. User can sweep upwards using linear sweeps.
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
XCITE 1200-2 Inertial Mass Excitation System
-
The Xcite 1200-2 Inertial Mass Excitation system provides a new dimension to structural testing. The ES-302 Exciter contains a 250 lb mass which is accelerated through a 2″ displacement by a hydraulic actuator. The 2,000 lb inertial force which is generated provides ample input to structures such as those shown below to perform low frequency seismic studies and high frequency rotating equipment analyses.
-
Product
General Purpose Pressure Sensors For High Frequency
-
PCB® Series 113B dynamic pressure sensors set the standard for extremely fast, micro-second response with a wide amplitude and frequency range. These characteristics allow them to excel in high-frequency applications, where minimum sensor diameter is required.
-
Product
Inductive Sensors
-
Inductive Proximity Switches, self contained, depend on the output of an oscillator for their operation. The oscillator resonant circuit uses an open core coil to produce a concentrated high frequency electromagnetic (RF) field, which emerges from the active surface of the sensor. If a metal target (or other electrically conductive material) enters this field, eddy currents will be induced in it, causing the resonating oscillator to be damped.
-
Product
Wideband Power Analyzer
2335A
-
Clarke-Hess Communications Research
The Model 2335A Wideband Power Analyzer is a precision, high accuracy, high frequency auto-ranging instrument which measures and displays true rms Voltage, true rms Current, and true mean Power over a frequency range from dc to more than 1MHz. Full scale Current and Voltage inputs are typically measured within 0.1% of the amplitude reading to at least 500kHz. The corresponding Power is typically measured to within 0.1% of the input Volt-Amperes to 250kHz and to within 0.2% of the input Volt-Amperes to 500kHz for loads having any Power Factor.
-
Product
LXI High Frequency Matrices
-
Pickering's LXI high frequency (HF) matrix modules are suitable for switching frequencies up to 50MHz. They have an impedance of 50 and uses SMB signal connectors or with a larger case size is uses BNC connectors. This HF matrix is designed to provide a simple and scalable bidirectional matrix for radio frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems.
-
Product
20GHz 30dBm RF Signal Amplifier
A10200
-
Model A10200 is an ultra-small footprint, ultra wideband, high power amplifier designed for high frequency, high power, signal amplification. With an ultra high bandwidth of almost 20GHz and up to +28dBm power into 50 ohms, the A10200 is the ideal complimentary amplifier to any signal source that needs an extended power boost for demanding applications.
-
Product
Gravity Handler
-
State of the art model, which features a high throughput capability, eight sites, and high and low temperature measurements, and meets all high-frequence contact requirements. Complete measures to prevent jamming and lead deformation enable high availability. This model is highly regarded by top users around the world because of its high throughput and high reliability.
-
Product
ME2PHF-B
101512
-
The mechanical and pneumatic version of the ME2 series can be easily and simply extended with the ME2HFK high-frequency insert, which also contains the shielded housing (dimensions of lower shielded housing: 212 x 240 mm). This means that both the ME2 and the ME2P with ME2HFK insert can test sensitive and transmitting assemblies - including those with a combination of transmitter and receiver - precisely and reliably without risking any consequences for your production. At the same time, interference with sensitive assemblies can be reliably ruled out. This is because it is particularly important for tests in the high-frequency range to reliably protect your test specimens against interference radiation from the environment.
-
Product
Differential Probe
DP-16K Series
-
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
Product
Track and Hold Data
-
Track and hold amplifiers are used to expand the bandwidth and/or high-frequency linearity of high-speed A/D conversion and signal acquisition systems. Track and Hold Amplifiers can be used in various applications including RF ATE Applications, Digital Sampling Oscilloscopes, RF Demodulation Systems, Digital Receiver Systems, High Speed Peak Detectors, Software Defined Radio, Radar, ECM & ELINT Systems and High Speed DAC De-Glitching.
-
Product
AC Power Source
APS-7000 Series
-
AC Power Source APS-7000 Series, the advanced direct digital frequency synthesizer (DDS) waveform is used to achieve high frequency stability, good continuity and accurate measurement.
-
Product
PID Controller
-
Liquid Instruments' new instrument features real-time frequency-domain conDesign your control system's frequency response using the interactive Bode plotBlock diagram view of the digital signal processing with built-in probe points for signal monitoring2 input channels, 2 output channels with control matrix for blending inputsIncludes single or double integrators and differentiators with low- and high-frequency gain saturationtrol system design capabilities.
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Spectrum Analyzer Plug-in
FreqAnalyst
-
This plug-in has been designed to provide extreme smoothness and high resolution for both time and frequency: unlike most spectrum analyzers, Blue Cat's FreqAnalyst is able to display continuous variations even with a very high frequency resolution, thanks to its unique smooth interpolation algorithms.
-
Product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
-
High Frequency Cartridge for HFP Series Probes
-
Product
Servo And VFD Filters
-
Operation of PWM-driven motors – servo motors and variable frequency drives (VFD) – causes several problems in equipment, including damage to the motor’s bearings due to leakage current causing electrical discharge machining (EDM) and damage to motor’s insulation. PWM motors also are a major source of EMI in equipment. These motor drive systems use pulsed power to drive the motors. As we are aware, the sharp edges of the pulses inevitably include high frequency components which can couple or radiate as noise to other parts of your system and cause unreliability, communication/control problems and EMC compliance issues.
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
Magnetic Material Analyzer
UI9730
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
-
Product
PDIV Tester for EV Motor
PDIV 500-T
-
Shanghai Dean Electrical Co., Ltd
Differing from partial discharge with high frequency pulse which produce sound and light phenomenon, the power frequency AC voltage reaches a certain threshold, can only produce instantaneous current leakage around the tested sample, it can be detected through discharge capacity (unit: PC) to evaluate partial discharge phenomena..The instrument PDIV 500-T is designed to put samples such as enameled wire, insulation paper/film, and electric motor stator in the High temperature / humidity environment chamber, applying a power frequency voltage with a programed rising speed, and prefect ground connection must be guaranteed , through the coupling capacitor as the medium, the continuous detection of discharge capacity against the voltages will create formulation between the Voltages and discharge capacities (pc), the software will find the discharge voltage threshold called PDIV.
-
Product
QDRII/DDRII/ QDRII+/DDRII+ SRAM
-
DDR II / II+ (Double Data Rate) SRAMs and QDR^(TM) II / II+ (Quad Data Rate) SRAMs are the ideal memory devices for next generation networking and communications systems. These ultra-fast devices can support high bandwidth systems that require memories capable of very high operating frequencies combined with low latencies and full cycle utilization.





























