Insulation
-
Product
Insulation Tester
Calibrated 1kV Megohmmeter
-
*Calculations (automatic)*Potential Index and Dielectric Absorption Ratios*Tests Continuity, Resistance and Frequency Measurements*Programmable Alarms*Insulation Test, Resistance, Continuity*Hazardous Voltage Alert (Icon) if voltage is >70 volts 5.) On Board Timer, +1/- 1 sec.
-
Product
Oil Breakdown Voltage Tester
DTL C
-
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.
-
Product
Terminal Test Kit (94 Pcs)
3601
-
Peaceful Thriving Enterprise Co Ltd
*Total: 94 pcs*Alligator Clip x 2 pcs*Testing Probe x 2 pcs*Flat Terminal x 48 pcs*Testing Needle x 4 pcs*1 to 2 Connector x 2 pcs*Round Terminal x 24 pcs*5K Variable Resistor x 2 pcs*Polarity Tester / Stroboscope x 2 pcs*Insulator Pierce Through Clip x 2 pcs*SRS Air Bag Replacement Connector x 2 pcs*Male / Female to Male / Female Extension Wire x 4 pcs
-
Product
GDGY Insulating Oil Tangent Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
It is applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.
-
Product
Oil Breakdown Voltage Tester
DTA IL
-
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Product
Digital (1kV below) Insulation Tester
2151 IN
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.
-
Product
Insulation Tester Calibrator
M191
-
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
Product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
-
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
Product
Test Points, Tips, Probes, Jumpers and Clips
-
Nickel Plated Steel Alligator Clips. PTFE Insulated Terminals and Test Point Jacks. Circuit Board Test Jacks and Plugs. Color Coded PCB Mount Test Points, Loop Style with Plastic Base for Snap-In Mounting. Surface Mount Test Points on Tape and Reel.
-
Product
Resistor Calibration Box
RCB-411
-
Standard Electric Works Co., Ltd
● The RCB-411 is used to verify and proof High Voltage Insulation Testers. Both Analogue and Digital Insulation Testers can be calibrated.● Caution: a. Before testing, make sure the front panel, terminals are clean and dry. If not, wipe them with cloth. b. Use high voltage silicone wires. Otherwise the reading will be incorrect.
-
Product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
-
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Product
Insulation & Multifunction Tester (LCD Display)
1155 TMF
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
Product
Digital Insulation Tester
1550C
-
The Fluke 1550C performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones.
-
Product
Analogue (1kV below) Insulation Tester
ST-1504
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Measures insulation(MΩ), continuity(Ω) and AC voltage.● Instant operation is possible with a push button, convenient timer is provided with automatic power off after three to five minutes to save the battery power.● LED (red) indication when testing insulation and continuity.● Use of a high efficiency and accurate DC-DC converter.● Most suitable for insulation resistance measurement of electrical household appliances, power line distribution and installation.
-
Product
Burn-in Room and Aging Test Chamber
-
Isolated type of burn-in room features: ●Separate the product and loading area, easy to control temperature and maintain. ●Temp. range: 40-70ºC±3/±5ºC, ●Temp. constancy: ±0.5ºC ●Uniformity: ±3ºC ●Test frame materials: painted stainless steel or a combination of forming aluminum ●Insulation: with PU foam ( doors with double glazing ) insulation, so that the internal temperature is not subject to external factors, to achieve power saving effect ●Product hierarchy placement, Selection of layer height in accordance with the requirements, convenient access ●Computer monitoring system is optional. ●Noise level:≤75dB Application Suitable for all kinds of electronic products, especially for products with heating characteristics Product and loading area should be separated Large-scale production
-
Product
Below Ground Insulator Tester
CE-IT
-
The CE-IT gives fast and accurate testing of below ground insulators and road crossing casings. This fully automatic unit tests the insulator without any adjustment by the operator needed.
-
Product
Enlarge Environmental Chamber
REXMED REC-480
-
MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
HV Test System up to 20000 Volt
-
Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
Product
Dielectric Insulation Analyzer
DIRANA
-
DIRANA uses dielectric frequency response (DFR) analysis in order to determine the condition of high-voltage insulation systems such as those in power transformers, bushings, cables and generators.
-
Product
Current Transformer
ST-30CT
-
Standard Electric Works Co., Ltd
● 30/5A - 150/5A● 2-3V A● Class 1● Insulation 600V
-
Product
Programmable AC Withstand Voltage Insulation Tester
-
Shenzhen Chuangxin Instruments Co., Ltd.
*Small volume, light weight *Easy to operate, has keyboard lock function *Provide 5 groups memory setting, each group has four kinds of work mode LCD display Voltage gradient rise by time, real-time analysis and look for breakdown point
-
Product
IST(5KV~15KV)High Voltage Micro Ohm Meter,Insulation Resistance Tester Kit
-
Chongqing Assen Power Equipment Co., Ltd
ISF High Voltage Ohm Meter has a large LCD screen gray backlit display, data storage, data access, alarm, and automatic shutdown functions.
-
Product
Partial Discharge Testing Equipment
AR700
-
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
Product
Installation Testers
-
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
Product
Insulation & Multifunction Tester (LCD Display)
4101 IN
-
Standard Electric Works Co., Ltd
● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
-
Product
40U (70") Insulated Bus Bar
BB-70-I
-
40U (70") insulated bus bar provides cabinets with recessed rail option and a convenient, isolated common grounding mechanism.
-
Product
Multifunctional Safety Tests
-
Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test
-
Product
Advanced Insulation Resistance Tester 1000V AC/DC
IRT807
-
UEi Test & Measurement Instruments
The IRT807 is a 1000V Advanced Digital Insulation Resistance Tester.