Reference Transformers
See Also: References, Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Zero Phase Current Transformer
MZL-30
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
Phase Shifting Transformer
-
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
Product
Current Transformers
-
Supreme Instrument Laboratories
Portable Low Tension precision grade multi ratio Current Transformers, housed in laminated wooden cabinet, wound primary with suitable terminals on highly insulated bakelite panel upto 100 Amps. For higher ranges, a centre hole is provided for passing primary conductors for desired range.
-
Product
1 Channel, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTA
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
AC Test Transformer
-
Shanghai Guantu Technology Co., Ltd.
How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.
-
Product
Current Transformers Test Set
-
Supreme Instrument Laboratories
The basic unit is sensitive magnetic comparator and also it incorporates electronic null detector to facilitate the balance. The reference Current 5A. or IA. obtained from Standard Current Transformer and in comparison to that the vector length and phase displacement is measured. The ratio error in percentage and phase displacement in minutes are directly compared and indicated on dials.
-
Product
COM Express® Type 2 Reference Carrier Board in ATX Form Factor
Express-BASE
Computer on Module
The COM Express approach of custom carrier combined with off the shelf system cores is an excellent solution when you need to customize but lack the time or quantity for a complete redesign. It fits most system integration projects with production volumes from 500 to 10,000 pcs per year. The COM Express concept has a great many advantages over full custom designs, it reduces engineering complexity, lowers the threshold for total project quantity and last but not least brings your product to the market in no time. The average time to design a carrier board is less than half the time of a full custom OEM board.
-
Product
COM Express Type 10 Reference Carrier Board
miniBASE-10R
Carrier Board
The COM Express approach of custom carrier combined with off the shelf system cores is an excellent solution when you need to customize but lack the time or quantity for a complete redesign. It fits most system integration projects with production volumes from 500 to 10,000 pcs per year. The COM Express concept has a great many advantages over full custom designs, it reduces engineering complexity, lowers the threshold for total project quantity and last but not least brings your product to the market in no time. The average time to design a carrier board is less than half the time of a full custom OEM board.
-
Product
Portable Single Phase Transformer
-
Supreme Instrument Laboratories
Portable single phase double wound transformers both step-up and step-down, natural air cooled construction, housed in well ventilated sheet steel cabinet duly powder coated. All the input and output terminals are brought out and terminated on highly insulated bakelite panels duly marked for easy connection.
-
Product
Reference Cells
-
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.
-
Product
Precision Multirange Voltage Transformers
WP-36000
-
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Current Transformer Analyzer
CT Analyzer
-
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
CONTROL TRANSFORMERS
-
Our control transformers are robust, flexible in design and come with short lead time. Basically an ideal solution for control panel builders who need transformers in a hurry.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Auxiliary Potential Transformers
-
Osborne Auxiliary Potential Transformers (Aux PT’s) are used in utility and commercial industrial power systems. Osborne works with our clients to identify the safety advantages of using auxiliary potential transformers (Aux PT’s) to establish protection schemes for high voltage equipment. Aux PT’s step the voltage down to safer levels, normally below 600 V AC.
-
Product
AC Reference Generators
SRB
-
Computer Conversions Corporation
The SRB Series are miniature, Bulk-head Mount, low cost AC reference generators to supply moderate power 2-115VAC excitation to Synchro's, Resolvers, LVDT's and related converters in COTS-Military and industrial applications for measurement, control, simulation and data communications.
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Sound Power Reference Source
Qref
-
Precision omni-directionallity in all directions, horizontal and vertical plane. This source has a frequency range of application between 100 and 8000 Hz (third octave bands) Despite only weighing 1.4 kg and having a diameter of 105 mm, it produces a maximum sound power level of Lw 104 dB.
-
Product
Current Transformer
CT
-
The split-core current transformers are easily installed with the snap on design.
-
Product
Power Transformer Monitoring
-
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.
-
Product
Transformer Winding Resistance Testers / TRT ? 2
TRT-2
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fast measurement: Test current 0.02A to 2A DC, Digital display of resistance and test current.
-
Product
Transformer Turns Ratio Testers
-
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
VARIABLE TRANSFORMER DC POWER
208163V
-
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
Product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
-
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
Product
FPGA Fast Fourier Transformation (FFT)
eXpert / Fast Fourier Transformation
-
Fourier Transform Analysis is Advanced On-board FPGA Technology a powerful signal-processing technique used in a wide variety of applications. GaGe’s eXpert FFT firmware allows CompuScopehardware to perform Fourier Analysis within its on-board processing FPGA.
-
Product
Intelligent Time Reference
TM-4™and TM-4/OEM™
-
The Intelligent Reference/TM-4™ and TM4/OEM™ are multi- purpose, GPS disciplined timing signal generators and frequency references in economical off-the-shelf and custom configurations. Intended for use in a wide variety of timing, synchronization and frequency reference applications, they are based on the most advanced architecture Spectrum has ever offered, and include the most popular features of Spectrum's core platform for current timing products.
-
Product
Shunt Voltage References
-
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.





























