Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
AC Measurement Standard
5790B
-
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74E
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Sematech Analysis and SEMI Standards Analysis
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Standard And Custom Targets
-
Santa Barbara Infrared manufactures a wide range of targets for visible, and infrared/FLIR electro-optical testing. These targets complement our complete line of Visible and IR test products. Our targets are designed to function with one of SBIR’s target wheels. Utilizing a variety of manufacturing techniques, including conventional machining, photochemical etching, electro-deposition, electrical discharge machining (EDM) and laser cutting. SBIR targets are manufactured to exacting mechanical tolerances. SBIR manufactures all of the targets specified by MIL-STD-1859 and the Tri-Service Guide for thermal imager testing.
-
Product
Automated Calibration
ORION
-
ORION automates the process of characterization and calibration of engines. It facilitates the calibration process by taking control of both the ECU calibration system and the test cell control system to run experiments as part of an automated calibration process. With connectivity to IAV’s EasyDOE, Mathworks’ MBC Toolbox and other DOE tools, ORION provides an extremely powerful environment for mapping an engine and generating the Engine Management System calibration tables. The modular design means the product can be configured to a users’ specific requirements and work practices, rather than having to adhere to rigid methodologies dictated by prescriptive software.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Hardness Calibration
-
Trescal provides full Hardness Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Hardness Calibration services can be delivered at your site or at our lab. Accreditations for our hardness calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
PAL Standard Pattern Generator
PG315P
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Mass Flow Calibration
-
Allow instrument interchangeability without affecting your process and meet ISO 9001 requirements easily and efficiently with Process Instruments’ Mass Flow Calibration and Repair Services.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-0
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
Product
Infrared Calibrators
-
Electronic Development Labs, Inc.
Designed to test, verify, and calibrate infrared thermometers, pyrometers, and thermal imagers for accuracy.
-
Product
Torque and Force Calibrators
-
Self-contained, semi-automated, multi-functional calibrator, which provides a rapid highly accurate and safe means for calibrating and testing a wide variety of torque and force measuring instruments.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
Automated CMM Calibrated for High-Production Shop Floor Inspection
CMM Master
-
The CMM Master provides process control by delivering optimal price and performance to your application. The system brings highly repeatable, thermally insensitive, versatile, and programmable inspection to the shop floor.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1W1S
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
SiTek Standard PSD
1L20_CP3
-
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2A
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Calibration Software
-
System Monitor is a software package for configuring and tuning automotive control systems. It has built-in support for motor sport systems and can be tailored to support third party control units.System Monitor not only allows you to tune data for your program versions, but also manages those versions on disk, allowing them to be located quickly for programming or modification
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52B
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
VR/AR/MR Calibration Platform
-
AR, VR and MR device calibration is critical for product performance. Leverage Averna’s standardized alignment platform to efficiently calibrate cameras and Inertial Measurement Unit (IMU) modules with supreme accuracy. Easily customize or upgrade the base platform into the automated quality solution to best fit your manufacturing requirements.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Panel Mount Calibrators
-
Practical Instrument Electronics, Inc.
Now you can panel mount PIE 820 & 830 Multifunction calibrators. As part of a calibration bench, the PIE 820PM or 830PM provide an accurate multifunction calibrator that is easy to use and may be removed for annual calibration. Panel mounting a multifunction calibrator is useful whether you are putting a calibration bench in your instrument shop, require a manual loading station in a control panel or for use as a built-in process simulator.
-
Product
Velocity Calibration
-
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.





























