product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I35-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
In-Line Speedometer Calibrator Module
Hypertech’s In-line Speedometer Calibrator Module is an in-line module to correct the speedometer and odometer for non-stock tire sizes and/or rear gear ratios. This module is perfect for vehicles with computers that don’t allow for tire size and/or rear gear ratio correction or re-calibrate for tire sizes and/or rear gear ratios outside the range of programmers.
-
product
Analyse-it Standard Edition
The powerful statistical analysis and regression you'd expect from an expensive statistics package.
-
product
Helmholtz Coils (Field Standards)
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
product
Standard Tensile Link
SL-3.0
The SL-3.0 is a cable connected Tensile Link available with capacities ranging from 1t to 500t. These devices can be used in various tension load monitoring applications for industries worldwide and combine high levels of performance with excellent value.
-
product
6GHz SMA Calibration Kits
CAL-SMA-6B
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.
-
product
Calibration and Repair
Traceable vibrometer calibration insures a high level of data quality, critically important for many applications in industry, science and medicine. Polytec service engineers ensure fast and efficient equipment calibration that is traceable to national and international standards, intended to be ISO/IEC 17025 compliant.
-
product
Standard Systems With Customization
When the cable assembly product offerings on the website – cable, connectors, and markers – do not meet the needs of your application, Teledyne Storm Microwave provides our Standard with Features (SWF) offering. SWF allows the customization of your cable assembly needs by discussing your needs with our Applications Engineering professionals and without needing a detailed specification.
-
product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
product
RTD Calibrators
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
Phase Angle Voltmeter, Industry Standard
2250A
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Dry Block And Bath Calibrators
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
product
Uniform Light Sources, Luminance Standards
Uniform light sources for the adjustment of pixels and intensity of image sensors and cameras as well as for the calibration of luminance and spectral radiance or in other words: Solutions for Imaging, Sensing & Remote Sensor Calibration.
-
product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-R
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
product
Ice Point Calibrators
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Power and energy calibrators
Three or single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
-
product
Trace Calibration Systems
Precise calibration is essential for most analytical instruments. We offer systems that provide controlled amounts of calibration gas, zero air or even standards from evaporated liquids. Browse our range of LCU systems.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Field Calibrator of Three Phase Energy Meter
SY3640
Hong Kong Songyang Industrial Ltd.
SY3640 three phase energy meter field calibrator is a high precious three phase energy reference meter; it uses the advanced technology and latest electronic components available in the world, and use high speed DSP as the main processor to ensure the accuracy and long time stability.
-
product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4-S
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50B
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
Gas Flow Standards
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
product
Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0B
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13