Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Cup, Straight Shaft Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G21
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Cup Reduced Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G12
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Calibration Devices For Spring Impact Hammer
CX-TF06A
-
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
Product
Rubidium Frequency Standards
-
Incorporating time-tested and field-proven technology, these rubidiums deliver high-precision time and frequency accuracy for measurement equipment. Products are available in VXI and PXI versions.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1R1S
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Capacitance Standard
GenRad 1417
-
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
Product
Standard Magnetizers
-
The selection of a magnetizing system begins with an analysis of the production requirements, including magnet material, magnet size, magnetizing orientation, number of poles, production speed, magnet measuring, and other operations that are necessary. After careful evaluations of these factors, and reviews of samples and/or drawings, our application engineers can recommend a system that will meet your requirements.
-
Product
Standard 1.18 (33.30) - 3.25 (97.00) Battery Probe
BIP-1
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 16Test Center (mil): 150Test Center (mm): 3.81Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 250,000Overall Length (mil): 323Overall Length (mm): 8.20
-
Product
Ultra Low Noise Disciplined Frequency 4220a Standard with Rubidium and OCXO Clean-Up Oscillator
-
Precise Time and Frequency, Inc.
The ptf 4220A is an Ultra Low Noise Disciplined Frequency Standard with rubidium and OCXO clean-up oscillator.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Standard Voltage 9 Pin D-Type Connectors for Pickering Products
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
GPS Frequency Standards
-
Precision Test Systems manufacturers' a full range of GPS and GNSS frequency standards that are disciplined to most of the worlds satellite systems.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Automatic Calibration Function oH Meter
AH-151
-
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
-
Your product description goes here.
-
Product
IEC60068-2-75 Spring Hammer Calibration Device
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is mainly used for the calibration of the spring hammer, which is based on IEC60068-2-75-1997 and GB2423.55-2006 standard design and manufacture, primarily for third-party testing organization, the National immigration department and appliance-related research institutes.
-
Product
Acoustic Calibrators
-
Acu-Vib Electronics Acoustic & Vibration
a portable precision device that generates a highly stable, known sound pressure level at a specific frequency. It is primarily used by sound engineers and technicians to verify, test, and adjust the accuracy of sound level meters and microphones before and after taking measurements.
-
Product
Standard Tensile Link
SL-3.0
-
The SL-3.0 is a cable connected Tensile Link available with capacities ranging from 1t to 500t. These devices can be used in various tension load monitoring applications for industries worldwide and combine high levels of performance with excellent value.
-
Product
Standard Test Lead Kit
U1168B
-
The Keysight U1168B standard test lead kit is compatible with the Keysight U1230, U1240, U1250, U1270 and U1280 Series handheld digital multimeters.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1A-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Calibration Executive Software
CalEasy Series
-
CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.
-
Product
Standard Gain Horns
-
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas





























