Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
RF Prototyping Kit
VXI-5501
-
* VXI-5501 has a Bare Copper-clad Prototyping Board for RF and microwave modules.* Includes a VXI-5524 Register Based Interface Board with 48 digital IO lines and a 16-bit VXI data bus.* User configurable model number, manufacturer ID, version and serial numbers identifies the module as from your company.* Includes a blank front panel, side shields, manual, layout aids and VXI-Kit hardware for a single slot wide C-size module.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
COMETEO Multi-Plate Radiation Shield
F8100
-
Newly developed meteorological screen for humidity and temperature transmitters. Passive solar radiation and weather shelter for meteo sensors.
-
Product
MP CI set
-
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
Product
SH68M-68M-EPM, Male 68 pin SCSI to 68 pin VHDCI, 0.3m
192288-0R3
-
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
Product
AC-DC Wide Adjust Output Power Supplies
-
*Universal input.*Power Factor Correction.*Output Inhibit*Constant voltage and constant current modes.*Voltage and current monitor terminals.*Voltage and current programming capabilities.*Short circuit and overload protection.*Thermal protection.*Low Profile.*No minimum load required.*Adjustable down to 0 volts (‘Wide Adjust’ models).*Internal EMI Filter and RFI Shielding.*Pluggable connectors for input and control wiring.*Remote Sensing.*‘Vout OK’ signal monitor.*‘Soft start’ operation.
-
Product
Active Loop Antennas / Magnetic Field Probes
-
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
Product
G10x - 15 Module Solution
-
This 15 Module Solution provides reliability while simultaneously engaging up to 3,200 signal contacts. The adaptable G10x integrates a wide variety of I/O options in various module configurations. Contacts are incorporated into cable assemblies for specific instruments. The ITA has a unique, removable EMI shielded cover which allows easy access to enclosed modules and contacts.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
PXI 32 x SPDT Reed Relay
40-110-121
-
Our 40-110 and 40-115 range of reed relay switching modules are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 96 pin male micro-D connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120/125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, for slaving up to larger switches or for operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board thus easing the construction of complicated wiring.
-
Product
Test Receiver
KH3932
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH3932 EM1 test receiver is a fully automatic test receiver and the main tool for EM1 testing. The frequency range of the KH3932 receiver is from 9kHz to 300MHz. Equipped with a power absorption clamp, it can meet the power line disturbance power test. After the artificial power network is configured, the power terminal disturbance voltage test can be carried out. The machine has fast test speed and maneuverability. Strong, stable performance, convenient test data processing and other advantages. The KH3932 receiver uses the USB interface to exchange data with the computer, which makes the transmission speed fast and the bit error rate low. Connect to the computer for testing and use the operating environment familiar to the operator to improve work efficiency.The equipped operating software saves the data of a variety of external equipment, and supports plug and play a variety of external test equipment. The software and hardware are developed by our company. The whole machine uses a fully enclosed structure, and the chassis uses highly conductive materials with good shielding effects. Due to the use of specific technologies and processes, the problem of its own resistance is fundamentally solved. The measurement results are in the international general report format, which can be saved in the computer's hard disk or transmitted through the network, printed out directly, and saved using a USB storage device. The report is rich in content and can be printed directly according to user needs without additional editing.The measurement receiver complies with the requirements of the national standard GBT6113.101 and the international standard CISPR16-1.
-
Product
Log Periodic Antennas
-
A.H. Systems' offers 13 Log Periodic Antennas. Each antenna is lightweight, compact, rugged and has been manufactured to ensure maximum gain, low VSWR and high power handling capabilities. Whether testing inside a shielded enclosure or outdoors, the antennas will display efficient performance characteristics through the broad frequency range of 80 MHz to 7GHz.
-
Product
Anechoic chambers
-
The anechoic chambers are built up as a modular construction. Due to individual modules any size of chamber can be manufactured. Big chambers may require an outer supporting structure or alternatively the shielding material can be attached direct to the building. The absorbers are fixed to rails bars or wooden base construction which is inserted into the shielding modules.
-
Product
SCSI-100 To 2*SCSI-50 Shielded Cable, 1m
PCL-10251-1E
-
SCSI-100 to 2*SCSI-50 Shielded Cable, 1m
-
Product
Ion Chambers
-
0.2 to 5000 mR/hr, 5 Ranges• Temperature Compensated• Retractable 1000 mg/cm² Beta Shield• High Background Zero Capability• Proportional Audio Output
-
Product
RF Test Enclosure, ≥100 DB Of Isolation, 300 MHz - 18 GHz
dbSAFE DUO
-
RF enclosures are now a necessity for testing wireless devices. The dbSAFE DUO offers unmatched isolation in its class; up to 100 dB* from 300 MHz to 18 GHz. The dbSAFE DUO shielded box has been engineered from the ground up to provide superior RF isolation and performance while being cost-effective. The dbSAFE DUO can be designed and manufactured to almost any size and dimensions.
-
Product
PXI 24 x DPST Reed Relays
40-115-122
-
Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.
-
Product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
-
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
Product
SMD Tweezer
U1782B
-
The Keysight U1782B is a tweezer to be used with the U1700 Series handheld capacitor and handheld LCR meters. For better noise immunity, the tweezer has a guard end to be connected to the meter´s guard terminal. The tweezer is now redesigned with a new shielded rigid cable to improve both usability and measurement stability.
-
Product
Receiver Protectors
-
Teledyne Lincoln Microwave has a proud heritage of designing and manufacturing world class Receiver Protector / Limiter products. Our devices are used across the globe, in the air, on the ground to shield mission critical systems from damage by synchronous and asynchronous sources of RF Power.
-
Product
Shield Boxes
-
Concentric Technology Solutions, Inc.
CTS can provide a customized integrated RF Shield Box or RF Enclosure Test Solution for manual or automatic testing at an off-the-shelf solution price. Many companies make RF Shield boxes, RF Enclosures or DUT fixtures, but only CTS bridges the gap by providing a complete integrated RF Shield Box or RF Enclosure testing solution for providing the RF shielding needed for repeatability within your budget and schedule.
-
Product
G6x - 9 Module Solution
-
This 9 Module Solution provides versatility in the same small footprint as the G6. This high-density Interconnect can simultaneously engage up to 1,920 signal contacts. The ability to add 3 iCon modules into the interface design provides up to 25% more I/O. The ITA has a unique, removable EMI shielded cover which allows easy access to modules and contacts.
-
Product
Cylindrical Inductive Proximity Sensor
GX-M SERIES
-
Panasonic Industrial Devices Sales Company of America
The GX-M Series line of Cylindrical Inductive Sensors offer models with a wide range of sensing distances that are available with shielded or non-shielded 2, and 3 wiring configurations.
-
Product
Blank Module, Receiver/ITA, 1 Module Position, 90 Series Modules
510104118
-
Blank modules are for unused module slots. The blank shielding module fills a module slot and shields signals between the modules. Blank modules fit in either ITA or receiver positions.
-
Product
SHC68-H1X38 High-Speed Digital Flying-Leads Cable Accessory, 1.5m
192681-1R5
-
76-Pin, Female Flying Leads to 68-Pin, Male VHDCI, Shielded, 50 Ω Digital Cable - The SHC68-H1X38 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments directly to individual header pins for use with a custom breakout fixture. The flying-lead cable has paired signal and ground lines for each channel to preserve signal quality. Each signal and ground line is designed to plug directly into any 0.1 in. header connector. It is a shielded, 50 Ω cable.
-
Product
Multi-Modular Cable Tester
MT-7051N
-
Tests RJ45 TIA568A/B (AT&T 258A), 10 Base-T, Token ring, RJ-11/ RJ-12 USOC and Coaxial BNC cable.Automatically check cable for continuity, short, open and crossed wire pairs.Coaxial cable port indentifies cable conditions including shorts, shield opens and center conductor breaks.Main unit and remote allow one person testing.Power source: DC 9V BatteryDimension: 102x106x28 (mm)Cable not include
-
Product
Multiplexer Switches
SMX-3XXX (Multiplexers)
-
The VTI SMX-3xxx Series of multiplexers deliver exceptional performance and reliability by implementing extensive signal path shielding and isolation. Available models with software configurable switch subsystems increase flexibility and help control costs by allowing a single module to be used for different testing requirements. Embedded virtual schematic control further simplifies setup and debugging, allowing all relays to be engaged independent of application software.





























