Data Acquisition Systems
sense, log and store information. Also known as: DAS
See Also: Data Acquisition, PCI Data Acquisition, DAQ
-
Product
Dynamometer Controls, Data Acquisition Systems and Instrumentation
-
Whether you want a basic engine dynamometer configuration that provides torque, rpm and power or need an advanced, full-featured test and measurement software package, Taylor has a data acquisition system that will serve your unique application without breaking your budget. Contact Taylor to discuss which instrumentation system and related accessories are right for you, and turn your testing challenges into success.
-
Product
PXI 2 Amp MUX, Single 8-Channel 4-Pole
40-635-103
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 2 Amp MUX, Single 32-Channel 2-Pole
40-635-002
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Sensing System
DAS
-
Our Distributed Acoustic Sensor(DAS) with excellent pattern recognition software can detect and locate the distributed thousanfs of acoustic events. Whenever any vibration or sound around its sensing fiber is detected, our DAS system will process the measured data in real-time and its pattern recognition software will recognize the types of the events, such as digging, pipeline leakage, fence breach, vehicle moving person walking. And, the detected events are reported to the alarm server to help operators take actions to protect theor facilities.
-
Product
Software
DASYLAB Lite
-
Dasylab lite software for operation of our line of THERMES Data Acquisition Systems. For customers who already have Labview or Dasylab no additional software is necessary. Recommended operating software is Dasylab Lite version 10. The lite version provides all the necessary functions to display and store temperature data in digital and graphical formats in real time. Users may customize the display to suit their particular application. The Dasylab Basic version provides additional features for data manipulation and statistical analysis.
-
Product
PXI High Density MUX 94-Channel 1-Pole
40-640-022-94/1
Multiplexer Module
This series of high density multiplexer modules feature a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector. It may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available for this 1-pole version).
-
Product
Dual 12x4 1-Pole High-Density PXI Matrix Module
40-520-405
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
CAN + OBD Network Data Converter
NC2
-
Add Vehicle Network based Data Acquisition to your existing fleet data acquisition systems for under one thousand dollars with the NC2. Great for NVH Tachometer applications.
-
Product
PXI Single 46x4 Matrix, 1 Pole Switching
40-524-021
Matrix Switch Module
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
2- to 8-Channel Anti-Alias Low-Pass Filter and Instrumentation Amplifier Card
AAF-3
-
The AAF-3 is a 2- to 8-channel anti-alias low-pass filter and instrumentation amplifier ISA bus plug-in board for front-end signal conditioning in PC-based data acquisition systems.
-
Product
PXI Dual 16x8 Matrix, 1 Pole Switching
40-532-021
Matrix Switch Module
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
High-speed USB DAQ System
Model DI-4208
-
USB Data Acquisition (DAQ) System. Eight armored analog differential inputs*. Programmable range per channel: ±2, 5, 10, 20, 50 100 V full scale. Up to 120 V rms without damage. 50 dB common mode rejection. Supports ChannelStretch™ multi-unit synchronization*. Adaptable low-pass filter per channel. Corner frequency set as a function of sampling rate. 16-bit analog-to-digital resolution. 160 kHz analog sample throughput rate. Seven digital ports*. Programmable per port as input or switch. Support for rate measurements to 50 kHz. Support for 16-bit counter.
-
Product
PXI Multiplexer, Single 24-Channel, 2-Pole
40-632A-021-24/2
Multiplexer Module
The 40-632A-021-24/2 is a single 24-channel, 2-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Test & Measurement Automation Services
-
Our flexible and collaborative approach delivers efficient, accurate, and robust test systems, as well as the tools to leverage test data for effective results analysis. We develop systems using a variety of software and hardware platforms (custom and off-the-shelf), data acquisition systems, and control methods. We are comfortable developing custom turnkey systems or working alongside your team on your current system under development.
-
Product
Multi-Channel Battery Testing
-
The Multi-channel system includes turnkey integration of Greenlight's environmental chamber, load bank, power supply and data acquisition system, all housed in 19" rack towers.
-
Product
PXI 2A Multiplexer, 2-Bank, 32-Channel 2-Pole
40-614-011
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Dual 16x2 1-Pole High-Density PXI Matrix Module
40-520-501
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 2A Multiplexer, 2-Bank, 16-Channel 4-Pole
40-614-012
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI Very High Density Mux 24 Ch 8 Pole
40-670A-022-24/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI MUX 8 Banks of 8 Channel Screened 1 Pole
40-610-021-S-8/8/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI 2 Amp MUX, Dual 4-Channel 4-Pole
40-635-107
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 12x4 Matrix, 1 Pole Switching
40-510-021
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
Flight Test Instrumentation Software
TTCWare
-
Curtiss-Wright Defense Solutions
TTCWare is a data acquisition system configuration and programming application. Using TTCWare, you can customize the behavior of your hardware and create parameters to sample data. Parameters can be inserted into the PCM format at user specified locations in order to achieve desired sampling rates. After creating a PCM format, you can program your hardware with your customized configuration.
-
Product
Instrument Grade Data Sensor
WISER 8000
-
TECAT Performance Systems, LLC
The TECAT WISER Model 8000 dual strain measurement and monitoring system is a wireless data acquisition system for measuring two external strain channels at high data rates up to 8kHz. The small, light, power-efficient, and non-invasive design enables strain measurements in a wide range of applications. With dual external sensor inputs two Micro-Measurements strain gauge bridges can be measured by a single system, for example to measure both thrust and torque loads simultaneously.The Model 8000 has a long range data transmission of >1,000 meters with up to +/- 0.025% FSR sensitivity for remote measurements. After initial setup using the WISER software interface, the system can be wired directly to your DAQ system, for seamless data collection.
-
Product
PXI/PXIe Very High Density Multiplexer, 49-Channel, 4-Pole
40-675B-002-49/4
Multiplexer Module
The 40-675B-002-49/4 (PXI) and the 42-675B-002-49/4 (PXIe) are 49-channel, 4-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI High Density Matrix Module, 16x16, 2-Pole, 2A
40-582A-001
Matrix Switch Module
The 40-582A is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 16x16 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 10 Banks of 16 Channel 1 Pole MUX
40-615-022-10/16/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration. Connections are made via a front panel 200-pin connector.
-
Product
CW Test Transmitters / Signal Generators
-
The WTX CW test transmitter family is particularly designed for field applications such as Inbuilding site modeling (model calibration), DAS injection / testing, walk-testing as well as outdoor path model tuning- thanks to its broad range of optional power amplifiers.
-
Product
PXI High Density Multiplexer, 1-Bank, 128-Channel, 1-Pole
40-610A-004
Multiplexer Module
The 40-610A-004 is a 1-bank, 128-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
High Temperature Clip-On Gages (700 C)
Model 7641
-
Jinan Testing Equipment IE Corporation
These COD gages use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7641 is ideal for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. All units can be displaced slightly in compression for ease of installation. The COD gage is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the COD gage. This system provides a number of functional enhancements, including: high speed digital output, built in calibration and tare functions, analog and digital filters, and more. The 7641 is readily interfaced with most existing test controllers, and may be directly connected to a data acquisition system or chart recorder, or directly to a PC. The 7641 may be used for strain controlled tests such as JIC.