Product
PXI 6U PXI High Density Matrix, 132x8 1-Pole
45-541-001
Matrix Switch Module
This 6U PXI Reed Relay Matrix Module is an ultra high-density reed relay matrix available in 132x8 format with 1- pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e9 operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
PXI 2 Amp MUX, Quad 8-Channel 2-Pole
40-635-009
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 2A Multiplexer, 2-Bank, 4-Channel 16-Pole
40-614-014
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Tri-Mode I/O Controller
SAS3816
-
Broadcom Tri-Mode SerDes technology enables seamless operation of PCIe, SAS or SATA storage devices in a single drive bay. The introduction of PCIe devices executing NVMe to the existing SAS/SATA infrastructure makes industry standard, hot-pluggable drive bays even more versatile. Whether you’re building external or cloud-based storage systems for high connectivity, or outfitting servers, the SAS3816, 16-port, 12Gb/s Tri-Mode SAS/SATA/PCIe Gen4 IOC provides choices for storage optimization by enhancing direct-attached storage (DAS) solutions.
-
Product
Amplifier-per-channel Multiplexed System
System 472
-
The NEFF System 472 (S472) DAS is a complete moderate-speed DAS for use in computer-based applications. The S472 is designed primarily for computer automated data acquisition in test facilities, laboratories and industrial plants or wherever a moderate-speed DAS is required.
-
Product
DAQ User Interface Software
DAPstudio 3.00
-
If you need to deliver a data acquisition system quickly and you want to develop a good user interface for it, then download DAPstudio 3.00 and see how that could help. You now can use the latest (full) version of DAP Measurement Studio software from Microstar Laboratories, maker of Data Acquisition Processor (DAP) boards and software, for an unlimited trial period at no charge.
-
Product
PXI Multiplexer, Dual 16-Channel, 2-Pole
40-630A-022-D/16/2
Multiplexer Module
The 40-630A-022-D/16/2 is a dual 16-channel, 2-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Indoor DAS Transmitters
-
Berkeley Varitronics Systems, Inc.
Lightweight DAS transmitters and high-speed receivers for the build-out, optimization and indoor coverage studies of in-building microcell networks and base station repeaters.
-
Product
VXI Module
VDSP-31
-
The VDSP31 is a VXI based, multi-channel data acquisition system and digital servo control module. The VDSP31 offers a complete solution for high performance closed loop applications. The VDSP31 has been designed to solve specific problems related to the control of hydraulic actuators. Signal conditioning modules can be combined on a per channel basis to configure the VDSP31 for load or displacement feedback.
-
Product
PXI Multiplexer Single 64 Ch 1 Pole
40-630-022-64/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole and 1-pole screened.
-
Product
Battery Testing Chambers
-
We supply a variety of test chambers for testing small battery cells to large lithium ion battery packs. Battery test chambers are supplied to a variety of industries including telecommunications, computer and automotive. With the goal of reducing automobile emissions and the development of electric vehicles, the need for lithium ion battery testing is even more critical. Our proven experience provides the most cost-effective solutions. Each test chamber is built according to specific test requirements and may be interfaced with battery cyclers, control & monitoring data acquisitions systems and other test equipment for a complete integrated test solution. All environmental chambers are designed with safety in mind. A variety of safety features are provided for reliability and abuse testing of batteries. These features may be incorporated into CSZ test chambers and tailored to the various hazard levels of EUCAR (European Council for Automotive R&D), a consortium of European car manufacturers. To better assess the hazard potential of tests, EUCAR has investigated hazardous situations and divided them into eight risk classes. The development of the safety equipment of our battery test systems is also based on this classification. For each hazard level, we recommend specific safety options that can be included with your chamber to meet your specifications to safety test your product. Together with our customers, we assess which safety devices are necessary for the respective test chambers.
-
Product
PXI 2 Amp Multiplexer, Single 4-Channel, 8-Pole
40-635A-104
Multiplexer Module
The 40-635A-104 is a single 4-channel, 8-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
DAS & Small Cell Products
-
*High power handling 750W Ultra-broadband devices support from 555 to 3800 MHz.
-
Product
PXI 2A Multiplexer, 4-Bank, 16-Channel 2-Pole
40-614-007
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 2A Multiplexer, 2-Bank, 64-Channel 1-Pole
40-614-010
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Single 16x12 1-Pole High-Density PXI Matrix Module
40-520-101
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
High-Speed MWIR Camera for Range & Science Applications
FLIR RS8500
-
The FLIR RS8500 MWIR infrared camera system is a high-performance thermal camera and infrared telescope combined in a single weatherproof housing, specifically designed for long-range tracking and measurement applications including military range, aerospace, and outdoor research. Built around a high-resolution 1280 × 1024 midwave indium antimonide detector with the ability to deliver data up to 180 frames per second, the RS8500 provides 24% more pixels and a 46% faster frame speed than the previous model. Multiple simultaneous data and video output options allow the camera to be easily integrated into most data acquisition systems.
-
Product
PXI Dual 16x8 Matrix, 2 Pole Switching
40-532-022
Matrix Switch Module
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
Product
PXI/PXIe Very High Density Multiplexer, 10-Channel, 16-Pole
40-675B-002-10/16
Multiplexer Module
The 40-675B-002-10/16 (PXI) and the 42-675B-002-10/16 (PXIe) are 10-channel, 16-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI High Density Multiplexer, 1-Bank, 64-Channel, 1-Pole, Screened
40-610A-016
Multiplexer Module
The 40-610A-016 is a screened 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe Very High Density Multiplexer, 198-Channel, 1-Pole
40-675B-002-198/1
Multiplexer Module
The 40-675B-002-198/1 (PXI) and the 42-675B-002-198/1 (PXIe) are 198-channel, 1-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
Dual 12x8 1-Pole High-Density PXI Matrix Module
40-520-206
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe Very High Density Multiplexer, 49-Channel, 4-Pole
42-675B-002-49/4
Multiplexer Module
The 40-675B-002-49/4 (PXI) and the 42-675B-002-49/4 (PXIe) are 49-channel, 4-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
Dual 16x8 1-Pole High-Density PXI Matrix Module
40-520-205
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
6U High-Density PXI Matrices
-
High-density matrices suitable for signal switching in ATE and data acquisition systems.
-
Product
Test Compliance
CTS Series 3.2
-
AMETEK Programmable Power, Inc.
The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.
-
Product
PXI Dual 12x4 1-Pole Matrix Module, Screened
40-511-021-S
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
PXI Very High Density Multiplexer, 24-Channel 4-pole
40-670C-021-24/4
Multiplexer Module
The 40-670C-021-24/4 is a 24-channel, 4-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).