DVB-T2
Digital Video Broadcasting – Second Generation Terrestrial
-
Product
24" Rackmount Drawer, Unshielded, 7"H x 24"D
DR-072424-S
-
Unshielded drawers with writing surface are constructed of 20 ga. CRS and are furnished with ball bearing chassis slides to provide smooth operation. Available for 19" and 24" rackmount in 20", 24" and 30" depths, with or without a keylock
-
Product
sbRIO-9223, Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
785480-01
Voltage Input Module
Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO-9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO-92233 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO-9223: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
Neutron Detectors
-
As a neutron has no charge, a neutron detector incorporates a neutron-to-ionisation particle converter.The incident neutrons are captured by the converter material which then produces (detectable) ionising particles by means of a nuclear reaction.Photonis gas-filled detectors are designed to detect thermal neutrons (En < 0.025 eV), so the capture cross-section of the detecting material must be as large as possible for this low energy. We therefore use 235U (580 barn at 20 °C) for our fission chambers, and 10B (3840 barn at 20 °C) for our boron-lined proportional counters.
-
Product
Plug-in Temperature Conditioners
PITC
-
The PITC, with a temperature range of -70 C to +177 C, was first introduced in the late 1950s by Bemcos Conrad/Missimer Division. Today, the modernized version of this system is the ideal solution where short run or infrequent tests are required, test specimens are unusual in size or shape, initial capital costs must be held low, or test needs are frequently changed.
-
Product
24" Rackmount Drawer, Unshielded, 3.5"H x 20"D
DR-032420-S
-
Unshielded drawers with writing surface are constructed of 20 ga. CRS and are furnished with ball bearing chassis slides to provide smooth operation. Available for 19" and 24" rackmount in 20", 24" and 30" depths, with or without a keylock
-
Product
Thermal Night Vision Rifle Scope
ThermoSight® R-Series
-
Built by the leader in infrared technology, the FLIR ThermoSight R-Series is the world''''s first line of thermal night vision rifle scopes for non-game hunting starting under $3,500. Compact and easy-to-use, the ThermoSight R-Series combines the features you want with the thermal performance you expect. The ThermoSight R-Series is the ideal night vision scope because it detects heat energy, instead of light. Conventional image intensified (I2) night vision scopes require illumination from moonlight or other sources, and can''''''''t reveal what''''''''s hiding in the shadows or in low-contrast environments like the R-Series.
-
Product
Stability Testing Chamber - Double Door Model
Q20
-
Canden stability testing chamber is capable of maintaining stable temperature set points of 25°c , 30°c & 40°c and corresponding relative humidity set points of 60%RH(@25°c), 65%RH(@30°c) and 75% RH(@40°c) with exceptional precision. The chamber has a wide operating temperature range of 18°c t to 40°c maintaining a stable temperature across the entire range.
-
Product
Microprobe Thermometer
BAT-12
-
The BAT-12 laboratory digital thermometer is Physitemp's most popular and best selling instrument due to its versatility, quality construction and low cost.The BAT-12 has 0.1°C resolution and super accuracy of 0.1°C ±1 digit between 0-50°C, 0.1°C ± 1 digit over full range.The temperature range is -100 to 200°C. The BAT-12 provides fast readings, usually within 2-5 seconds depending on the temperature probe in use.
-
Product
Temperature Measurement IR Sensors & Detectors
ST60 High Temperature
-
A single-channel silicon-based thermopile that will withstand operating temperatures of 225C, with a small active area of 0.61mm x 0.61mm in a TO-5 package. The reduced height package functions as an internal aperture. Two thermistor options provide ambient package temperature measurement. Currently only available with 8-14um silicon window. Time constant of 18ms with Nitrogen encapsulation gas delivers a very low Temperature Coefficient of Responsivity of -0.4%C. This detector has a very short thermal shock response to ambient temperature change.
-
Product
20W to 30W - Single Output / Multiple Output
PXE Series
-
*Industry Standard 2" x 1.6" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
NTC Clamp Temperature Probe
Si-RM2
-
This Si-RM2 temperature probe accurately and simultaneously provides real-time superheat/sub cooling calculations. It measures temperature from -40 to 150 °C (-40 to 302 °F), and comes with wireless connection low energy.
-
Product
79W to 153W - Single Output
CUS200LD Series
-
*Convection or Conduction Cooled*Up to 206W Peak Power Capability*Low 31mm Height*-40°C Ambient temperature start up
-
Product
Ethernet
-
Ethernet and fiber optic networks are critical components in business service delivery. The DataScou... t family of multi-service network analyzers enables providers to equip technicians to install and troubleshoot next generation networks effectively, while continuing to support legacy transport services. Tempo Communications offers service providers powerful, all-in-one solutions that span future and past technologies, making the transformation from legacy transport circuits to advanced multi-gigabit services an easy one. The DataScout family is designed to ensure maximum efficiency while lowering costs associated with installing, maintaining, and troubleshooting networks.Show less
-
Product
Low-overhead Coverage Analysis For Critical Software
RapiCover
-
* Collect coverage for Ada, C & C++ (inc. MC/DC) on-host & target* Reduce test builds needed for analysis on constrained targets* Save time with efficient merge and mark verification workflow* Simplify verification by integrating with your CI tool* Produce evidence for DO-178 and ISO 26262 certification
-
Product
Robust RISC-based DIN-rail Fanless Embedded System With I.MX 6UL Processor, COM, LAN, DIO 2-in/2-out (Sink Type) And 2 PCIe Mini Card Slots
IRU131-SI
-
*RISC-based (i.MX 6UltraLite) processor 528 MHz*512MB DDR3 SDRAM onboard*8GB eMMC flash onboard*2 PCI Express Mini Card slots (Wi-Fi, 3G/4G or LoRa)*1 isolated COM port*1 isolated DIO 2-in/2-out (Sink Type)*Power input range of 9V to 48V DC with terminal block*Embedded Linux operating system (Yocto)*Wide operating temperature range from -40°C to +70°C*Supports OPC UA
-
Product
FD-11603, 8-Channel, ±10 V Voltage Input Device for FieldDAQ
785639-01
Voltage Input Module
The FD-11603 can measure up to eight channels with a voltage input range of ±10 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11603 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages. The FD-11603 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11603 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11603 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11603 is ideal for test cell and outdoor environments.
-
Product
4 Thermocouples/RTD Ch
APCI-3200-4
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
Temperature Input Module
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
CO2 Concentration Transmitter
T5340
-
The transmitters are designed for online measurement of temperature (C or F), relative humidityand carbon dioxide concentration of air without aggressive ingredients. Measured temperature andrelative humidity are recomputed to following humidity expression: dew point temperature, absolutehumidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
8 Port BRI-S/T ISDN Simulator
BRI-8ST
-
The unit has 8 S/T ports allowing ISDN basic rate terminal equipment to be connected together just as if they were connected through the ISDN network.
-
Product
Refractometer Calibration Oils
-
Calibration Oils are one of the most commonly used materials for calibrating refractometers as they have good traceability, particularly to NIST. Having a high temperature co-efficient, Calibration Oils are best used where strict temperature control is adopted either by Peltier or external waterbath between 10 and 75 °C as well as with refractometers operating at ambient by making use of supplied tables or an RI/°C Temperature Calculator as long as the prism temperature is reliably known.
-
Product
Hydrogen Analyzer
EMGA-921
-
EMGA-921 Hydrogen analyzer: It's a "New flagship model” for H analyzer and user friendly product.This is an hydrogen elemental analyzer with high accuracy and repeatability suiting to cutting-edge technology's R&D as well as quality control in the market of steel, new materials, catalyst and so on. This is a new generation model optimized to fit to user's requests.
-
Product
Ultra-Compact, Fanless, Low-Power Edge Computing Platform Powered By Intel® Processor N Series Or Atom® Processor X Series
MXE-230 Series
Industrial Computer
The MXE-230 Series computers, powered by the Intel® Processor N Series or Atom® Processor X Series, deliver low power consumption at just 12W. With an ultra-compact size of 165 x 120 x 62 mm (1.2L), they are ideal for space-constrained environments. The system supports up to 16GB DDR5 4800MHz memory, operates in temperatures from -20°C to 60°C, and offers two independent 4K 60fps display outputs. It also includes multiple I/O expansion options, such as M.2 and adaptive function modules, along with built-in TPM 2.0 for enhanced security.
-
Product
Kelvin Test Contactor
ecoAmp
-
ecoAmp™ Kelvin test contactor has a durable monolithic pin design with low and stable contact resistance. It is a high-power cantilever kelvin contactor with a patented spring and tip design for optimum heat dissipation. This ensures best reliability, long spring life and high yield even under highest current and temperature requirements. Featuring extended Automotive temperature range -60 ̊C to +175 ̊C, capable to stand thermal stress during high-power test. The contact motion is decoupled from the test board.
-
Product
KW Phase Array Radar Jamming System C, X, Ku, K, Ka And V Band
-
Digital Step Phase Shifter. Digital Step Attenuator. RF Solid State High Power Switch. Front End Low Noise . mplifier for Feedback. Transmit Solid State Power Amplifier Matrix 4x4, 8x8 or 16x16. Ultra Wide Band Flat Panel Antenna. Rotary Joint 360 rotation capability.
-
Product
Field-installation Type Turbidity Meter (Four-Wire Transmission, High-sensitivity)
HU-200TB-H
-
HU-200TB-H connects flow-through type turbidity sensor (SS-120-H) and measures turbidity. It accurately measures turbidity in the range of low to medium concentration (10 degrees) by the 90-degree transmission scattering method with less stray light.Optimal for control and monitoring of wastewater treatment and production processes.
-
Product
Mini Fiber Optical Switch at Single Mode Latching 1310/1550nm 5V with LC/PC Connector
SUN-FSW-1x4
-
Guilin GLsun Science and Tech Group Co., LTD
GLsun 1*4 Optical Switch micaro optical switch informationFeatures•Low Insertion Loss•Wide Wavelength Range•Low Crosstalk•High Stability,High Reliability•Epoxy-free onOptical Path•Latching and Non-latchingApplications•F&D in Laboratory•System Monintoring•OADM•MAN(Metropolitan Area Network)•Network Security and MonitoringSpecificationsParameters Unit SUN-FSW-1×4Wavelength Range nm 850±40 / 1300±40 1260 ~ 1650Test Wavelength nm 850 / 1300 1310 / 1550Insertion Loss 1, 2 dB ≤1.0Return Loss 1, 2 dB MM ≥ 30 SM ≥ 50Crosstalk 1 dB ≥ 55PDL dB SM ≤0.1WDL dB ≤0.25Repeatability dB ≤±0.02Operating Voltage V 3.0 or 5.0Voltage Pluse Width(Latching) ms ≥ 20Durability Cycles ≥ 10 MillionSwitching Time ms ≤8Optical Power mW ≤500Operating Temperature ℃ 0 ~ +70Storage Temperature ℃ -40 ~ +85Relative Humidity % 5 ~ 95Dimension mm (L)33.5×(W)25.5×(H)9.5 ±0.2Note: 1 Within operating temperature and SOP.2 Excluding connectors.GLSUN 1x4 fiber optic switch micaro optical switch
-
Product
High Temperature Component Test Fixture
16194A
Test Fixture
Measure both axial/radial leaded devices and SMD within the temperature range from -55 to +200°C.
-
Product
8 Channel Sample & Hold and Signal Conditioning Board for Group3
-
All channels provide for voltage division ahead of transient suppression before going into the S&H ICs. Channels that are sampled and held use a common sample and hold pulse that samples while high and holds while low. Jumpers on each S&H chip allow buffering of analog signals where sample and holds are not required. An advantage to the buffers is that it provides a high input impedance for high impedance voltage dividers.
-
Product
Cable Assembly, 50-Pin D-Type, Female to Unterminated With Cut Ends, 2m HV, Exit Towards Pin 1
A050DF5-C-HA200
Cable Assembly
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.





























