Product
User-Serviceable Photometers
8177
-
TSI''s Automated Filter Tester Models 8127 and 8130 have been used for respiratory filter and filter media testing by leading regulatory authorities and hundreds of manufacturers for over 20 years. These testers are 42 CFR 84, EN 143, ISO 23328-1 & GB2626 compliant. Cleaning the photometers in these testers used to require sending the assembly to the factory for service.
-
Product
Demonstration Boards
SAMPULSE50GHz and SAMPULSE70GHzANT
-
The SAMPULSE50GHz and SAMPULSE70GHzANT are demonstration boards for Furaxa InP single channel sampler/pulser ICs. The SAMPULSE50GHz model contains a 2.4mm combined TDR input/output connector to the common sampler/pulser node in the IC. The SAMPULSE70GHzANT is similar, except that instead of a single-ended 2.4mm connector, the sampler IC's differential inputs are fed from a bowtie antenna. In both models, the IC's differential sampler output is converted, using an AD8009 op amp, into a single-ended ground-referenced output that is sent to an SMA jack labeled SAMPLER OUTPUT.
-
Product
Differential Pressure Instruments
-
The testo 512 differential pressure meter is available as four models. This model has a measuring range from 0.0.29 psi and is ideal for measuring pressure differences at filters and for carrying out pitot static tube measurements in air ducts at air flow speeds between 16 and 180 fps.
-
Product
Crossed-Roller Bearing Linear Stage ,13mm Travel XY,Sensitivity 1um
NFP-2461
-
Model: NFP-2461 Crossed-Roller Bearing Linear Stage ,13mm Travel XY,Sensitivity 1umDetails&Spec: Please refer to NFP-1461 Specification,It is combinated by2pcs NFP-1461(C,SR,SL
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Hybrid Verification Platform
HES-DVM
-
HES-DVM™ is a fully automated and scalable hybrid verification environment for SoC and ASIC designs. Utilizing the latest co-emulation standards like SCE-MI or TLM and newest FPGA technology, hardware and software design teams obtain early access to the hardware prototype of the design. Working concurrently with one another they develop and verify high-level code with RTL accuracy and speed-effective SoC emulation or prototyping models reducing test time and a risk of silicon re-spins.
-
Product
8-Channel 200 MHz, 16-bit A/D with Virtex-7 FPGA - 6U VPX
Model 58760
-
- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Four or eight 200 MHz 16-bit A/Ds- 4 or 8 GB of DDR3 SDRAM- PCI Express (Gen. 1, 2 & 3) interface up to x8- Sample clock synchronization to an external system reference LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Glycerine & Propylene Glycol Refractometer, Freeze Point °C
PA203X-006-009-016-019
-
Celsius model – The Palm Abbe Glycerine & Propylene Glycol Refractometer is designed to provide the freezing point and percent concentration of both glyercine and propylene glycol antifreeze solutons. This instrument will test glycerine and propylene glycol percent concentration by volume and freezing point in degrees Celsius.
-
Product
Neon Bar Checker
9195
-
TAKK?s Model 9195 Neon Bar Checker offers a quick and inexpensive means of determining if static eliminator bars are functioning. The conveniently small pen size unit indicates that each bar emitter is performing properly by the activation of a neon light signal.
-
Product
WaveLink ProBus2 Platform/Cable Assembly for 4-8 GHz WaveLink Amplifiers.
WL-PBUS2
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Sensor Products: Weld Force Gage
90061
-
Model 90061 is a self-contained, portable measurement system which allows auditing of the pinch force generated between the electrodes of resistance spot welders. Resistance welding uses a pair of electrodes to clamp two base metals firmly together prior to and during application of electrical current. Poorly clamped parts result in a defective joint. A correctly clamped assembly aids in reducing the resistance in the joint and allows the current flow to properly heat the base metals to weld the part.
-
Product
Right Angle Waveguide to Coax Adapters
-
Fairview Microwave right angle waveguide to coax adapters include millimeter wave frequency ranges with models in the K-band (18 to 26.5 GHz) up to the V-band (50 to 65 GHz). These right angle waveguide to coax adapters offer excellent VSWR as low as 1.29:1, while also providing insertion loss performance as low as 0.3 dB. Waveguide sizes available for these new 90 degree coaxial adapter models include WR-42, WR-28, WR-22, WR-19 and WR-15. These coax to waveguide adapters in a right angle design are ideal for numerous applications requiring a transition from coaxial cable to waveguide or vice versa, including SATCOM, wireless communications, industrial, test and measurement and defense systems. Fairview’s new waveguide to coax adapter products feature a right-angle configuration, those with 2.92mm connectors use a UG-style square waveguide flange, 2.4mm and 1.85mm connector versions use a UG-style circular waveguide flange. Both male and female connector options are available in each right angle waveguide to coax adapter frequency band.
-
Product
Voltage Input Device For FieldDAQ
-
The Voltage Input Device for FieldDAQ measures up to eight ±10 V channels with 24-bit resolution and simultaneous sample rates up to 100 kS/s/ch. Some models can power sensors, such as pressure sensors, with up to 24 V per input channel. This device offers 500 V channel-to-channel isolation, protecting instrumentation from high-transient voltages. Additionally, the device is IP65 and IP67 rated to be dust-proof and water-submersible, can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. It has an integrated network switch for simplified daisy chaining and provides tight synchronization over time sensitive networking (TSN) for distributed data acquisition systems.The Voltage Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Live PD Emulation
-
Flexibly Mimic Class 0 to 4 Powered Device Per PSA/PSL-3000 Test Port. Configure up to 192 Simultaneous IEEE 802.3 PD’s. User-Defined Class 0 - 4 Powered Device Modeling with or without Cable Loss. Emulate 802.3at PoE-LLDP Negotiations and Power Adjustments. Monitor Multi-Port Live Emulation Status. Available to PSA-3000 and PSL-3000 Platforms as optional license feature.
-
Product
Microwave Testing
120
-
The MODEL 120 PICOPROBE® sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe®, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.
-
Product
Chemiluminescence 03 Analyzer
Model T265
-
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
Product
Lightning Generator
2654-1
-
The Solar Model 2654-1 Lightning Generator synthesizes electrical impulses needed for testing susceptibility to transients induced in aircraft equipment by lightning strikes.
-
Product
Transverse and Diametral Extensometers
-
3 models cover most any test requirement and can be used with axial extensometers at the same time. Miniature and standard units, also r-value units. Available options cover temperatures from -265 to +200 C (-450 to +400 F).
-
Product
Benchtop Rubidium Frequency Standard
FS725
-
Stanford Research Systems, Inc.
The FS725 integrates a rubidium oscillator (SRS model PRS10), a low-noise AC power supply, and distribution amplifiers in a compact, half-width 2U chassis.
-
Product
Polarimeter
ADP400 Series
-
The ADP400 Series from Bellingham + Stanley are single wavelength polarimeters suitable for sugar, food, chemical and pharmaceutical industries. These polarimeters are available with or without XPC - Xylem's patented internal Peltier temperature control system. Both models use standard polarimeter tubes with a maximum length of 200mm. For fast performance in the Peltier controlled version, stainless steel tubes should be used. Low volume samples are also catered for with the addition of stainless steel, luer taper tubes.
-
Product
Microscope Cameras From ZEISS
Axiocam Family
-
In contrast to digital cameras for photography or industrial inspection, many aspects of the microscope cameras are optimized to meet specific requirements of applications in science, research and documentation. As each application has very specific requirements, there is a wide range of different digital camera models to choose from. Different pixel sizes, for example, regulate camera sensitivity and spatial resolution. Lower pixel count enables higher frame rates and larger sensors offer better coverage of the field of view.
-
Product
Receivers
Series 32
-
Semco’s Series 32 Receivers are the optimal design for interfacing the GR 2270 style (VG) test fixtures. Featuring Semco’s patented CAM/TRAC® design, the Series 32 Receivers provide a locking system that assures consistent contact throughout the entire interface. With a full 5/8″ stroke, the Series 32 Receivers allow additional clearance for coax and custom block applications. They are available with or without vacuum ports. Models include: Bench Top, Slope, 19” Rack Mount, Dual 19 Rack Mount, and Dual Benchtop configurations.
-
Product
Field Meters
DG-OHM Compact
-
The DG-OHM Compact is the UNAOHM model that best responds to installers' requests regarding size, weight, ease of use, all of which, however, faithfully maintaining UNAOHM performance.
-
Product
CO2 Laser Spectrum Analyzer
-
The spectrum analysis screen has a response time of 1/4 seconds and permits the instrument to resolve all the CO2 rotational lines. The Model 16-A is light, portable and can easily be introduced into laboratory setups.
-
Product
Pressure Comparator (System F)
Type T
-
AMETEK Sensors, Test & Calibration
Type T hydraulic comparator (System F) is a self-contained high volume pressure source capable of producing pressure up to 15 000 psi. It is ideal for testing gauges and setting hydraulic relief valves and pressure switches. Multiple models are available for hydraulic oil, water, or both.
-
Product
UV Fluorescence Sulfur Dioxide Analyzer
Model T100
-
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
Product
Signal Amplifier
9100A
-
Model 9100A was designed as a general purpose, wide band and high voltage amplifier however, with specific applications in mind. It is built in a small case size to save space and cost but without compromising bandwidth and signal integrity.
-
Product
Anaerobic (Inert) Ovens
-
The IPH models are hermetically sealed ovens, allowing them to be filled with non-oxidizing gas such as carbon dioxide or nitrogen for anaerobic heat treatment or temperature-characteristics testing.
-
Product
High-Performance JTAG Emulators
XDS560 Series
-