Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
Product
Precision Low Power FGA™ Voltage References
ISL60002
-
The ISL60002 FGA™ voltage references are very high precision analog voltage references fabricated on Renesas' proprietary Floating Gate Analog technology and feature low supply voltage operation at ultra-low 350nA operating current. Additionally, the ISL60002 family features guaranteed initial accuracy as low as ±1.0mV and 20ppm/°C temperature coefficient. The initial accuracy and temperature stability performance of the ISL60002 family, plus the low supply voltage and 350nA power consumption, eliminates the need to compromise thermal stability for reduced power consumption making it an ideal companion to high resolution, low power data conversion systems.
-
Product
Charge Meter
NK-1001A/NK-1002A
-
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
Product
2WD Dynamometers
MD-250 Series
-
The MD-250 uses its powerful eddy current power absorber, a frictionless, air-cooled braking device, to enable it to apply variable and steady state loading. A complete control and data acquisition system lets you design a wide range of tests or select from a host of pre-configured tests included with the standard system.
-
Product
Radius, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Electrical Calibrators
-
We offer different electrical calibrators for electrical quantities. We mainly offer products for DC signals related to process calibration, such as current, voltage, resistance and frequency.
-
Product
PXI Single 4x4 1-Pole 10A Power Matrix
40-551-003
Matrix Switch Module
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
Product
Instantaneous Relays
-
An Instantaneous Relay is one in which there is no time delay provided intentionally. As the current coil is an inductor, there would be a certain delay to reach the current in the coil to its maximum value.
-
Product
Complete Graphical Power Quality Analysis System
PK5064-PRO+
-
The PK5064-PRO+ is the top choice for comprehensive power quality studies, energy audits, load studies, harmonic analysis, and more. Wide-range flexible current probes allow you to get into tight and confined spaces, wrap around large conductors, and measure almost any AC circuit that comes your way.
-
Product
PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-01
Analog Input Module
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
Product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
-
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1T1-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Primary Injection Test Equipment
-
High current injection units for primary testing of over current relays and circuit breakers.
-
Product
Common Mode Chokes
-
Common Mode Chokes, as the name implies, are designed to attenuate and filter common mode noise within an electric system. The key parameters for a common mode choke are the current rating (to ensure the part does not overheat within the application), the impedance versus frequency (to ensure it is optimized to attenuate the desired frequencies), the isolation voltage (to ensure it meets board level requirements between the line and neutral phases) and safety isolation (to ensure it meets the safety requirements of the end-application). It is important to remember that common mode chokes cannot saturate in the application (under normal use) as they are designed to ensure that the line and return currents are balanced.
-
Product
PXI High Voltage Power Multiplexer, Quad 6:1
40-331A-003
Multiplexer Module
The 40-331A-003 quad 6:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
Product
Cryogenic 4K Probe Cards
-
Over the last 20 years the Celadon Engineering team has developed an expertise in cryogenic materials which has resulted in a solid reputation in the industry for producing extremely stable cryogenic on-wafer probe cards as well as DUT probing solutions. These Cryogenic probe cards have all the benefits of Celadon’s Crash Resistant™ probe technology but with the ability to probe as cold as humanly possible. Celadon’s cryogenic solutions vary from standard VersaTile™ footprints which interface to positioners to innovate custom PCB based designs to allow for flexibility when testing at these very cold temperatures. Lakeshore cryogenic wire is used in standard DC solutions for high density cable-out designs to support high pin count applications. During the development process, Celadon works closely with the cryogenic prober vendor to ensure the integrated solution is optimized for current and future testing needs.
-
Product
8x4 Power Matrix, 2-Pole, 2xGMCT
40-550-902
Matrix Switch Module
This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.
-
Product
68 Pin 1.27mm Pitch Micro-D Connector & Cable Accessories
-
The 68 Pin 1.27mm Pitch Micro-D Connector is used on high-density PXI modules that require 1A current rating and voltage handling up to 150Vdc.
-
Product
AC / DC Current Clamp
HT9025
-
HT9025 has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1.
-
Product
24 TTL Channels, Programmable I/O
TL1
-
Function module TL1 provides 24 channels of TTL/CMOS transceiver functionality as either inputs or outputs. The transistor-transistor logic (TTL) employs transmitters with multiple emitters in gates having more than one input. TTL offers high switching speed and relative immunity to noisy systems. CMOS sensors provide image sensing technology by converting light waves into signals that are small bursts of current. These waves can be light or other electromagnetic radiation.
-
Product
Battery Data Logger
BDL-3927
-
Kongter Test & Measurement Co., Limited
BDL-3927 is updated Battery Data Logger to meet IEEE measurement standards for battery voltage, string voltage, current and ambient temperature. It is customized from 12V to 700V for different battery systems. And it has easy expansion for all battery systems. With wifi communication, you could easily view complete data and generate test report in the PC software.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1A-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1L24-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Sound Level Meter
831-LOWN
-
Easily make low noise measurements to 6.5 dB A-weighted using the Model 831-LOWN sound level meter paired with the 378A04 low noise microphone and preamplifier. Due to the innovative design of the 378A04 which uses a prepolarized microphone and ICP (constant current) interface, the combination produces a highly portable system that is battery powered and intuitive to use for measuring low noise levels.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1T-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Megohmmeter Insulation Tester
AMIC-30
-
The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.
-
Product
Single Phase Secondary Injection Test Set
T200A
-
T200A Single Phase Relay Testing Kit is the best universal secondary injection test set for engineers who need to do all single phase relay test and other basic primary testing which may require single phase long-term high current injection.
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3A-1
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Miniature Linear Motor Stage
M-661 · M-662
-
Physik Instrumente GmbH & Co. KG
M-661 and M-662 PILine translation stages offer accelerations to 5 g with millisecond response and velocities to 500 mm/sec in an extremely compact package. Providing travel ranges to 20 mm, they are among the smallest motorized translation stages currently on the market. Both models are designed for open-loop operation (a similar closed-loop stage with linear encoder is available as model M-663. The M-662, with its square footprint, is also suitable for use in XY configurations. For applications where the smallest dimensions are essential, the P-652 micro stage is offered.





























