Insertion Loss & Return Loss
-
product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A
40-192A-012
The 40-192A-012 is a PXI fault insertion switch using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
product
PXIe-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
780587-14
PXIe, 7-Channel, 40 A PXI Signal Insertion Switch Module—The PXIe‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
product
SIM, Module, ITA, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510171102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
Dielectric Loss Tangent Testing Instruments
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
product
Insertion Flow Meter
SPI Mag
The SPI Mag Insertion Flow Meter provides a highly cost-effective solution for the accurate measurement of liquid flow in closed conduit, pressurized pipe applications. Unlike conventional magnetic meters, the SPI Mag's cost is independent of pipe size.
-
product
Adapter Rails (for High Speed Inserts), i2MX, Receiver, 88 Pos, 11 Slot
510143001
Allows use of SIM VTAC patchcords in an i2MX receiver. Accommodates 11 single-slot inserts.
-
product
PXI 34x4 Signal Insertion and Monitor Matrix
40-525A-001
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.
-
product
PXI Fault Insertion Matrix Modules
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
product
Channel Insertion & Encoding
ATX’s encoder products provide a cost-effective and space-efficient solution for digital transmission and/or insertion applications. ATX’s fully integrated wall or rack mount “single unit” line of products are ideal for inserting security camera video into MDUs, inserting barker or information channels into hotels and other commercial properties, for digital simulcast applications, and for digital delivery of PEG or hub site specific programming.
-
product
ITA, i2 MX, EMI, w/ 2 Hybrid Module Inserts, XL Backshell (XL Bend Radius and Cable Exit)
410130132
This model i2 MX includes 2 Hybrid Module inserts. Each module insert includes 8 Mini Power/Coax and 8 TriPaddle positions. The XL-sized backshell allows for a greater cable bend radius and large cable exit which accommodates larger, high speed cables or a high volume of twisted pair combinations. The max cable bundle eff diameter= 1.67".
-
product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch
40-190B-002
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
VTAC Vertical Header Insert
The VTAC vertical header insert is designed to mount on custom PCBs. Can be configured as a backplane connector and daughterboard connectors. Also sold as a set under 610151108.
-
product
Signal, Patchcord, ITA, 72", QuadraPaddle Insert, Single Ended
7-151924000-072
Signal, Patchcord, ITA, 72", QuadraPaddle Insert, Single Ended
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
Adapter Rails (for High Speed Inserts), i2MX, ITA, 88 Pos, 11 Slot
510144001
Allows use of SIM inserts in i2MX ITA. Accommodates 11 single-slot inserts.
-
product
OPTICAL LOSS TEST SET (OLTS) MQJ KIT
4000-1025
The OLTS (Optical Loss Test Set) - MQJ Kit includes a soft, padded carrying case with strap that is provided to protect all of the components during transportation and/or storage.
-
product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
product
ITA, i2 MX, EMI, w/ 2 Hybrid Module Inserts
410130204
This model i2 MX includes 2 Hybrid Module inserts. Each module insert offers 8 Mini Power/Coax and 8 TriPaddle positions. Includes front protective cover.
-
product
PXIe-2515, 35-Channel, 0.25 A PXI Signal Insertion Switch Module
780587-15
PXIe, 35-Channel, 0.25 A PXI Signal Insertion Switch Module—The PXIe‑2515 is a multiplexer switch module that enables connectivity by routing high-speed digital I/O (DIO) signals between a device under test (DUT) and an NI high-speed DIO device or a parametric measurement device. You can use modules such as PXI Source Measure Units (SMUs) and PXI Digital Multimeters (DMMs) with high-speed digital devices. With the PXIe‑2515, you can perform parametric tests on digital pins without external connectivity or impedance mismatch challenges.
-
product
Loss Meter
L2000
3-in-1 as loss meter, light source, and power meter As loss meter Measure fiber loss at 1310nm and 1550nm As light source Single-head selectable output wavelength of 1310 or 1550 nm Ultra high output stability 0.05dB High output power preset at 0 dBm, or at customer-defined value Selectable CW, 270 Hz, 1KHz or 2KHz modulated output As power meter Calibrated outputs at 850, 1310, 1490, 1550, and 1625nm Data storage, logging, and PC up-loading Interactive measurements via PC Calibration on-site with customer's own standard if needed Selection of relative/absolute power measurement Display measurement in dB, dBm, mW, uW, nW Resolution 0.01dB; absolute accuracy 0.25dB For both single-mode and multi-mode optical fiber Small size, easy for field applications Light weight, less than 0.2Kg Auto power shut-off Enable / Disable Auto laser shut off at above 60oC Rechargeable battery, Battery-full and Battery-low indicator Changeable receptacle connector FC, SC, ST
-
product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A
40-193A-002
The 40-193A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
product
MX Series - i2 Modular Inserts
VPC i2 MX inserts offer standard and hybrid transmission options for both wired and PCB solutions.
-
product
Silicon Steel Sheet Iron Loss Tester
DX-30SST
DX-30SST Silicon Steel Sheet Iron Loss Meter adopts SCM technique and analog electronics technique, the magnetic circuit of permeameter adopts low loss silicon steel iron core, it is a small tester for measuring the characteristics of silicon steel sheet, met the requirements of tracing the brand of silicon steel sheet.
-
product
SIM, Module, Receiver, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510170102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
Penetration-Resistant Insert Flexing Tester
UI-FT05
Penetration-Resistant Insert Flexing Tester, also named as Steel Midsole Flexing Tester, is used to test penetration resistant inserts flexing resistance. As described in EN 12568, ISO 20344, the inserts shall exhibit no visible signs of cracking, disintegration or delamination after having been subjected to 1 *106 (one million) flexion cycles.
-
product
Digital Program Insertion Auditor
Torque DPI
The DPI Auditor supports the ANSI/SCTE 35 2001 standard that defines a fully digital mechanism to control remote splicing equipment via cueing messages embedded in the transport stream. The core of the standard is centered on an SIT (Splice Information Table) which can contain a schedule message or an insert message.
-
product
PXI-2515, 35-Channel, 0.25 A PXI Signal Insertion Switch Module
778572-15
35-Channel, 0.25 A PXI Signal Insertion Switch Module—The PXI‑2515 is a multiplexer switch module that enables connectivity by routing high-speed digital I/O (DIO) signals between a device under test (DUT) and an NI high-speed DIO device or a parametric measurement device. You can use modules such as PXI Source Measure Units (SMUs) and PXI Digital Multimeters (DMMs) with high-speed digital devices. With the PXI‑2515, you can perform parametric tests on digital pins without external connectivity or impedance mismatch challenges.