Flux
the rate of flow.
-
Product
Radiometric Probe for UVA Irradiance
LPUVA03…Series
-
The LPUVA03 probe measures irradiance (W/m²) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m²) in the UVA (315 nm…400 nm) spectral range. Thanks to a new type of photodiode, LPUVA03 is blind to visible and infrared light.
-
Product
Net Pyrradiometer
CN1-R
-
The Middleton CN1-R Net Pyrradiometer measures the net total radiation flux (solar, terrestrial, and atmospheric) downward and upward through a horizontal surface. It is suitable for solar energy studies in agriculture and meteorology.
-
Product
Fluxmeter
-
Measures changes in magnetic flux, as detected through a Helmholtz or similar coil arrangement.
-
Product
Measuring Stations
-
The main application is the measurement of the flux density on the surface of multipole magnets or components with magnets. A large amount of measuring stations is built for rotors.
-
Product
Fluxmeter
480
-
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
Product
Signal Analysis
Cross-Spectrum FFT Analysis
-
The program Cross narrow-band spectrum is used for evaluation of the interrelation between the signals’ parameters obtained from the two primary transducers installed at various parts of the controlled object. This program can be used for detection of noise source location, for sound absorption level evaluation and the researched object acoustic properties control, for evaluation of space-time distribution of the directional energy flux (Poynting vector), for the ground cross-section FR characteristic evaluation (Nakamura method), etc.
-
Product
Hall probes
-
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.
-
Product
Radiometric Detectors
-
Radiometric detectors are built by using selected, stability tested high-grade Si-photovoltaic cells. They are all equipped with individually produced and matched color glass filters. They are available in different sizes for irradiance and radiant flux measurement, both in temperature stabilized laboratory and general purpose form.
-
Product
Sensor Technology for Measuring Heat Flux, Humidity, and Temperature
Uval gt Building
-
uvalgt Building calculates the physical values that matter for buildings, such as heat flux (U-value), humidity and temperature. The measurement kit provides construction professionals with solid data during damage investigations, final inspections of construction work and renovation planning.
-
Product
Flux Leakage Tester For Detecting Surface Defects In Hot Rolled Black Steel Bar
130MM ROTOFLUX® AC
-
Highly sensitive AC flux leakage is especially well suited to test hot rolled black steel bars and rods that have surface conditions which used to make finding shallow defects very difficult, if not impossible.
-
Product
Instrument Systems LED And Display Measurement
-
Konica Minolta Sensing Americas, Inc
Instrument Systems is a frontrunner in developing state-of-the-art light measurement equipment, software, and accessories, taking great pride in constructing products that provide fast, accurate readings to ensure precise data for laboratory, production and quality assurance testing. All Instrument Systems products have stringent quality and performance requirements to ensure that customers get the highest quality equipment. As a leading supplier world-wide, they provide cost-sensitive support to a diverse clientele to help them measure luminance, flux, intensity, illuminance, and chromaticity of LEDS, lamps and displays throughout all aspects of product development and production.
-
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
Measuring Devices for Magnetically Hard Materials
WB10
-
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.
-
Product
Luxmeter
Digilux 9500
-
Instrument Systems Optische Messtechnik GmbH
The Digilux 9500 of the Optronik line is a high caliber luxmeter for the precise measurement of illuminance, luminousintensity in the lab, or determination of luminous flux with an integrating sphere. It is equipped with a state-of-the-art photocurrent amplifier and microprocessor technology, and offers multiple operating and display functions with an excellent price-performance ratio.
-
Product
Diesel Engine Tachometer
GE-2500
-
The GE-2500 diesel engine tachometer uses rotation speed of an alternator to measure engine rotation speed. With FFT calculation, this tachometer achieves reliable and stable measurement for both diesel and gasoline engines.The OM-1500 is a compact type detector designed for measuring rotation speed of an alternator. It detects magnetic flux leakage from an alternator. It is used to combine with the GE-2500. (The OM-1200 can also be used with the GE-2500.)
-
Product
Lamp-Based Calibration Light Sources
-
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
Hall Effect Measurement system
HMS-3300
-
Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.
-
Product
Magnetic Field And Permeability Measurement
MAGNETOMAT 1.790
-
Foerster Instruments, Incorporated
The MAGNETOMAT 1.790 is a measuring system for the precision detection of magnetic flux density and relative permeability. The MAGNETOMAT software is used for displaying the measured values and saving and exporting data. The wide range of probes facilitates optimal adjustment to the conditions of the application, such as the measurement of relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys. Further applications include the long-term monitoring of the magnetic environment, e.g. prior to installing magnetically sensitive devices, and the localization of ferrite enclosures in stainless steel and NE materials. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
Product
Optical Meters
-
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
Product
Accessories
-
Hunan Linkjoin Technology Co., Ltd.
Linkjoin accessories - electromagnet, core test fixture, epstein frame, DC permeameter, AC permeameter, reference magnet, magnetic flux fixture, solenoid, helmholtz coil, temperature controller, etc
-
Product
Reference Magnet
-
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
Product
Phosphorus Valved Cracker
-
The patented Valved Cracker for Phosphorus is uniquely tailored to provide a controlled and reproducible P2 flux from a solid phosphorus charge. The multi-zone crucible is designed for in situ conversion from commercially available red phosphorus to the more reactive white phosphorus with its advantageous evaporation characteristics.
-
Product
Flux Meter
NF-100
-
NF-100 can perform stable high accuracy measurement because noise and drift are reduced by the structure of digital counter and integral V/F converter with use of operational amplifier.
-
Product
ESD Safe Fume Absorber
-
ESD safe, carbon-activated fume absorber. Flux creates "pine resin", which creates noxious fumes. These fumes cause headaches and nausea. This unit quickly removes these fumes from the work area and filters them safely. Only this newly developed unit, mounted on its versatile 37" arms, allows easy movement to effectively remove these irritating fumes fast.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
N2O/H2O Trace Gas Analyzer
LI-7820
-
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems. Pair it with the LI-7810 CH4/CO2/H2O Trace Gas Analyzer or LI-870 CO2/H2O Analyzer for CO2 and CH4 measurements at your site.
-
Product
GO-2000 Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.