Flux
the rate of flow.
-
product
CO2/H2O Analyzer
LI-870
The LI-870 CO2/H2O Analyzer is a versatile analyzer for publication quality data that is simple to deploy, use, and maintain. A combination of precision and stability alongside a rugged and fieldable design makes it ideal for survey and long-term research focused on fluxes of soil CO2.
-
product
Dopant Source
Attain precise and stable control of relatively low fluxes for dopant constituents in molecular beam epitaxy (MBE) through this compact dopant source. Its small thermal mass gives it excellent responsiveness, reproducibility, and stabilization for advanced doping profiles, plus consistent flux uniformity across an entire platen. Efficient cell heating minimizes thermal load.
-
product
High Accuracy Spectrophotocolorimeter
LMS-3000
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
product
Photometers & Colorimeters
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
product
XRF
O Series
The O Series combines high performance with a small x-ray spot size. This is made possible by the poly-capillary focusing optics system that replaces the collimator assembly installed in standard Bowman systems. The optics are designed to focus the x-rays coming from the tube exit window to a very small spot size (80μm FWHM) while retaining virtually 100% of the tube flux. So instead of attenuating the x-rays that can’t fit through the small apertures, as is the case with collimator systems, the poly-capillary optics assembly allows almost all of the x-rays from the tube to reach the sample. The result is much greater sensitivity for testing very small components or thin coatings. Shorter test times can achieve even better repeatability when comparing optics systems vs. a similar sized collimator.
-
product
Fluxmeter
DX-201
DX-201 digital fluxmeter is a precise magnetic measuring instrument, adopted low drift electronic integrator design and production. The most important features are test response quick, without data lose in the testing process. In the process of test samples flux by the Czochralski method, fast pull and slow pull datas are consistent, fine features especially shows in repeated measurements and regression testing. It can measure magnetic flux or magnetic moment matched with different fixtures according to users’ requirements.
-
product
Digital Fluxmeter
ChenYang Technologies GmbH & Co. KG
A Fluxmeter is an electronic integrating, digital display instrument. The Fluxmeter can be used not only for the measurement of the magnetic flux of permanent magnets, but also for quality control and sorting of magnetic products. Its versatility makes the employment possible in laboratory enterprise as also in production.
-
product
GO-SPEX100 Goniospectroradiometer
Hangzhou Everfine Photo-E-Info Co., LTD
GO-SPEX100 delivers photmetric, colorimetric, electrical comprehensive test function for LEDs, and built-in precision temperature control platform,not only for measuring the specific temperature of the photometric and colorimetric parameters of LED, but also to measure the characteristics curve of its photometric and colorimetric performance with temperature.The test parameters include: spatial luminous intensity distribution curve, luminous flux, spatial spectral distribution, relative spectrum, absolute spectrum, color parameter, forward current and forward voltage, etc.
-
product
Magnetic Particle Inspection
Shanghai Xianda Denshijiki Industry Co.,Ltd
Using the "leakage magnetic flux" phenomenon generated from the scratches, the magnetic powder (or fluorescent magnetic powder) of the ferromagnetic material scattered on the surface by magnetizing the specimen is adsorbed to the scratch. Observe this and detect scratches.
-
product
Broadband Light Meters With Integrating Sphere
Broadband light meters with integrating sphere for measuring laser power (W) and luminous flux (lm).
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Soil Heat Flux Sensors
Soil heat flux sensors may consist of several thermocouples whose measurements are averaged, a single thermopile, or a single thermopile with a film heater. These sensors measure the rate of energy transferred through a surface. Data regarding the amount of energy stored in soil as a function of time is used in energy-balance and Bowen-ratio flux systems.
-
product
Underwater Quantum/PAR Sensors
Photosynthetic radiation is essential for the growth of the photosynthetic organisms such as corals. The wavelength range from 400 to 700 nm is PAR (Photosynthetically Active Radiation) or PPFD (Photosynthetic Photon Flux Density). Apogee quantum/PAR sensors are calibrated to measure the number of photons of light across this range.
-
product
Offline Stator Core Testing
Iris Power EL CID Evolution
The EL CID Evolution provides offline testing of inter-laminar insulation breakdown within a stator core. The only alternative to the Iris Power EL CID Evolution test is the Ring Flux (full flux) test. The Ring Flux test requires large power supplies, considerable manpower, and expensive infrared viewing cameras.
-
product
Hall Effect Measurement system
HMS-3300
Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.
-
product
Hall (Magnetic) Sensors
Small, compact axial and transverse Hall generators for measuring flux density. Available for use at cryogenic temperatures.
-
product
DMD Illuminators
Innovations in Optics' UV LED illuminators are ideal for TI’s larger DLP chipsets. LumiDL™ and Lumi3D™ optical design provides highly uniform flux density over large areas. Radiant flux is confined to 12° acceptance half-angle and DLP active area.
-
product
Integrating Sphere Based Spectroradiometer Systems
Spectroradiometer systems with integrating sphere for the measurement of UV-VIS-NIR spectral radiant flux (W/nm) and luminous flux (lm) and chromaticity metrics.
-
product
Helmholtz Coil
In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.
-
product
Adjustable Liquid Metering Valve
ASYMTEK DV-07
The DV-07 dispenses low to medium viscosity fluids for a variety of applications from microdots to volume fill. The DV-07 valve tolerates aggressive fluid formulations including acid-based fluids, reactive adhesives such as cyanoacrylates, solvents, and fluxes.
-
product
Hall Effect Measurement system
HMS-3000
Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.
-
product
LED Fast-Scan Micro-Spectrophoto Colori meter
8000
Shenzhen Chuangxin Instruments Co., Ltd.
The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.
-
product
Hall probes
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.
-
product
Heat flux plate
HFP01
Hukseflux Thermal Sensors B.V.
The HFP01 heat flux plate (also called heat flux sensor) offers a solution for measuring heat fluxes. HFP01 is the world's most popular sensor for heat flux measurement in the soil as well as through walls and building envelopes. By using a ceramics-plastic composite body the total thermal resistance is kept small.
-
product
PPID-2000 Photosynthetic Photon Intensity Distribution Test Unit
Hangzhou Everfine Photo-E-Info Co., LTD
It is mainly used for testing plant lighting products. With the EVERFINE GO-R5000 goniophotometer system, it can realize the measurement of plant photosynthetic photon intensity distribution (μmol/s/sr) in the whole space. In addition, the device can also realize the test of photosynthetic photon flux, far red light photon flux, photosynthetic radiation efficiency and other parameters, referring to DLC, ASABE, DIN, GB, CQC and CSA related international plant lighting standards .
-
product
PHOTO-2000Z Multiphotometer
Hangzhou Everfine Photo-E-Info Co., LTD
PHOTO-2000Z can be used for luminous flux (supporting integrating sphere) and illuminance test, portable design, high test accuracy, not only suitable for laboratory, quality inspection department, R&D department, but also for industrial and commercial field measurement.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
E1 Testers
GAOTek provides a large collection of high quality, affordable E1 testers that are specially manufactured to speed up the ethernet maintenance time and work efficiency for sale to the United States, Canada and Globally. These devices consist of PING, router trace, a port location tool, a loop-back tool and offers a variety of Ethernet diagnostic functions. These E1 Ethernet test instruments are all incorporated with test tools for E1, V port, and Gigabit Ethernet link repairs, and failure diagnosis. E1 Ethernet testing devices are user-friendly, can be used in Ethernet cable tests, flux error code tests, connectivity performance, traffic testing, ethernet wire testing, and bandwidth verification. As these devices help in measuring and proving performance for criteria Ethernet networks they are commonly used in the RFC2544 performance test.
-
product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.





























