Force
exerts an influence.
See Also: Compression, Crimp Force, Pull Force, Pull off Force, Push Pull Force, Peeling, Tension, Gravity, Electrical, Magnetic
-
product
Physical
This category covers test equipment for verification of resistance to heat, fire, tracking, mechanical stress, endurance, impact, force, torque, dimensional accuracy & similar related parameters as required by national and international safety regulatory agencies. These equipment are used to check Electrical WiringAccessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Many of these test equipment are common to many standards and are essential for routine test purposes.
-
product
Emergency Beacons
Emergency beacons that utilize satellites to alert search and rescue forces of a distress location.
-
product
Drill Tool Dynamometer
Unitech Scales And Measurements Pvt. Ltd
Unitech offers tool dynamometers to measure cutting forces on various machines like lathe, drill, milling machines. All three direction forces are measured simultaneously and displayed. Tool dynamometers are useful to study, analyse the optimum feed, speed and depth of cut on different materials. The dynamometers are also available in various capacities as per customer requirement.
-
product
Motorized Test Stands
Imada offers basic and advanced motorized test stands that are available in Standard, High, and Low speeds.Use ZTS or ZTA force gauges with MX, MX2 or EMX Series test stands to enable force control and non destructive testing.
-
product
Life Cyclic Durability Testing
Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.
-
product
High-Speed AFM
Is a type of atomic force microscopy (AFM) that, unlike conventional AFM, can take an image very quickly and with relatively low imaging force, therefore allowing for visualizing the dynamic behavior of biomolecules.
-
product
Cobra Temperature Forcing System for ATE/SLT Test Applications
31000R
Cobra is the most advanced, compact,powerful temperature-forcing system on the market. Cobra is an adaptable solution to the ever-increasing thermal demands of post silicon validation and device characterization.
-
product
Signal, Contact, ITA, TriPaddle,7 Amp, 20-24 AWG
610110108
Primary mating contact 610110101. (May mate with other Receiver contacts, as well.)Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)600 Volt Max. with Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1T24-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Quartz Charge Force Rings
Ring-style sensor configurations measure dynamic compression. Tension measurements are also possible if the unit has been installed with proper pre-load.
-
product
Micro Power, Contact, Receiver, 21 Amp, 12-14 AWG
610142101
Primary mating contact 610143101. (May mate with other ITA contacts, as well.)Specifications Operating Current 21 amps continuousContact Resistance 1.5 mOhms max.Dielectric Withstanding Voltage (DWV) 1500 VDC min.Contact Body BrassContact Plating 30µ" Au over 100µ" NiContact Termination CrimpCycle Life 10,000 cyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.23
-
product
Impact Testing
Educated Design & Development, Inc.
1250 g body includes release mechanism and striking element guide.250 g striking element comes with cocking knob and hammer head, polyamide face, is hemispherical with a radius of 10 mm, has a hardness of HR85-100.60 g release cone with a 10N release force.Single Impact Force models range from a 0.2 J Hammer to a 2.0 J Hammer.Custom padded carrying case included.
-
product
1 KN Henry Scott Grips
Henry Scott grips are useful for clamping plate and tape specimens of soft, flexible materials for tensile testing. Specimens are held by rollers on the upper and lower grips, which feature a self-clamping action. To minimize specimen slippage, the grip body opposite the roller, where the specimen contacts, is curved and features a parallel-grooved surface. During tensile testing, the self-clamping action applies increasing clamping force to the specimen as the overall force increases to help hold the specimen in place.
-
product
Bench Power Supply, Adjustable, Fixed, 3 Output, 0 V, 32 V, 0 A, 3 A
72-13600
*Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details
-
product
Load Cells & Force Transducers
BLH and Nobel Weighing Systems offer a wide variety of load cells and force transducers, ranging from the unique KIS load cell and weigh module to the VPG transducers range of products. Our many years of experience, our state-of-the-art instruments, and the exceptionally broad range of components that go into our systems allow us to deliver high-quality solutions tailored to your needs.
-
product
BGA SMT Adapters
Giga-snaP™
Giga-snaP™ 0.75, 0.8, 1.0, and 1.27mm pitch BGA Surface Mount Feet Adapter line of products provide an inexpensive and reliable method for attaching BGA chips to target board. The product line consists of patented female sockets with machined pins epoxy over-molded into an assembly that matches a particular BGA pattern. The epoxy over-molded female BGA socket is soldered to a PCB using standard soldering methods. A corresponding male pin BGA adapter, to which the user attaches their BGA chip, is plugged into the female socket on the board thus interconnecting the chip and the system is ready to go. The SMT adapters have the same solder ball types as the chips they are emulating. These adapters have less than half of the insertion force of competitive adapters, shorter electrical path for highest speed, and can be solder reflowed numerous times. A complete description and drawings of Giga-snaP™ 0.75, 0.8, 1.0, and 1.27mm pitch BGA Surface Mount Feet Adapters can be found at the tables shown below.
-
product
Schottky Mixer and Detector Diodes
Macom Technology Solutions Holdings Inc.
Schottky diodes are majority carrier diodes formed by plating a layer of metal on a layer of doped semiconductor, which forms a rectifying junction. The type of metal and the type of dopant in the semiconductor determines the diode’s barrier height, which is a measure of the amount of energy required to force the diode into forward conduction. MACOM produces Si Schottky diodes as well as GaAs Schottky diodes for use as signal detectors or in frequency mixers.
-
product
Tracking Index Test Apparatus
CX-L19
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
product
High Precision Compression Type Load Cell
HR II
A high-precision compression-type load cell is a sensor that accurately measures compressive (pushing) forces, designed for applications requiring very tight accuracy and reliability. It works by converting a downward force into an electrical signal, often using strain gauges to measure deformation, and is used in demanding fields like calibration, manufacturing, and medical equipment.
-
product
Mini Power, Contact, ITA, 65 Amp, 8 AWG
610115124
Primary mating contact 610116112. (May mate with other Receiver contacts, as well.)Mini Power contacts carry up to 65 amps continuous current, 480 VAC. Maximum resistance is 1 Milliohms.Specifications Operating Voltage & Current 65 Amps Max. Continuous – 8 AWG40 Amp Max. Continuous – 12 AWG30 Amp Max. Continuous – 14 AWG25 Amp Max. Continuous – 16 AWGContact Resistance 1 mOhms Max.Dielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 1000 MOhms Min.Contact Body BeCuContact Plating 50µ" Au over 100µ" NiContact Termination SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 3.37
-
product
Signal, Contact, ITA, TriPaddle, 7 Amp, 26-28 AWG
610110169
Primary mating contact 610110167. (May mate with other Receiver contacts, as well.)Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type E, Ø1.50mm, 155gf
K100-E150155-SKAU
K100 Series, Pitch 100mil, Tip Style E, Tip Diameter Ø1.50mm, Spring force 155gf, Steel with Gold Plating.
-
product
ThermalAir Desktop Series Temperature Forcing System
ThermalAir TA-1000A Desktop System
The ThermalAir TA-1000 high capacity thermal air stream system is used for temperature testing, fast thermal cycling, and device temperature characterization of components, hybrids, modules, PCBs, and other electronic and non-electronic assemblies at precise temperature from -25°C to +200°C.
-
product
Coax, Contact, ITA, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102132
Primary mating contact 610102133. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter contact – BeCuContact Plating Center conductor shield –30µ” Au over 100µ” NiContact Termination Center conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 800 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
Atomic Force Microscope
AFM
Atomic Force Microscopes are the most widely used SPM microscopes. They can be applied in fields that span from surface science, semiconductor technology, magnetic media, polymer science, optics to biology, chemistry and medicine.Absolute positioning with an accuracy of 2 nm.
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, Male Adapter, .025" Round Post (Adapter Pin)
610138117
Primary mating contact 610138100. (May mate with other Twin Female contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1I8-10
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
EO/IR Surveillance Systems
Multi-sensor systems for perimeter surveillance, security and force protection are available in a variety of lens and sensor combinations, and can be customized to meet any mobile or stationary mission requirement. These systems may be operated independently or in a fully integrated sensor network.
-
product
Furniture Test Equipment
chair seat drop impact durability testing machine for chair drop durability is used to evaluate the ability of the chair to withstand heavy and abusive impact forces on the seat. It can also to evaluate the ability of chairs to withstand fatigue stresses and wear caused by downward vertical force(s) on the seat. -
-
product
Force Data Acquisition Software
SW-1X data acquisition software is for force gauges with RS-232 output.SW-2X data acquisition software is for collecting force and displacement data from RS-232 output force gauges, with a -s test stand.Force Recorder data acquisition software is for ZTS & ZTA force gauges with USB output. Force Recorder Pro collects both force and displacement data with ZTA gauge and FA test stand.





























