product
P2662B General Purpose Probes
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
product
Power Probes
RkP-400 Series
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
BIP-12 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 394Full Travel (mm): 10.00Recommended Travel (mil): 315Recommended Travel (mm): 8.00Overall Length (mil): 1,220Overall Length (mm): 31.00
-
product
Manual Fixture Kit With Mass Interconnect Cassette Interface, Max number of probes (2N) 1000 units, Max UUT 580 x 400 mm (wxd)
CMCSK-04-01
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
Probes, Magnetic Field
EM-6881 | 480 KHz To 30 MHz
The EM-6880, EM-6881 and EM-6882 Magnetic Field Probes operate in conjunction with any 50 ohm input impedance receivers.
-
product
BARE BOARD TEST PROBES
Probe Technical DataMechanicalMINIMUM CENTERS: .100 (2.54)FULL TRAVEL: .160 (4.06)WORKING TRAVEL: .107 (2.72)OPERATING LIFE: 1,000,000 cyclesElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current60 18 mOHMS mean63 60 mOHMS meanMaterials and FinishesPLUNGER: Heat treated beryllium copper60 24 Kt gold plated over nickel63 24 Kt gold plated over nickelBARREL: Nickel silver60 24 Kt gold plated ID and OD over nickel63 No FinishSPRING: Music Wire, 24 Kt gold platedover nickel
-
product
Threaded High Temperature Probes
-80 ° C + 220 ° C [ -112 ° F - +428 ° F ] - used in climate chambers - perfect for machine builders.
-
product
Switch Probes
A Switch Probe is a spring contact probe and receptacle combination that is normally open, and after a designated travel the switch probe closes. The most common use for switch probes is in the cable harness testing industry. The switch probe is used to verify the correct location of a terminal in a connector while checking the retention force as well. Switch probes also verify the presence of nonconductive components such as caps for connectors or devices on a circuit board. Smiths Interconnect offers three standard sizes of switch probes.
-
product
Probes with Pyranometers and SICRAM module
LP471PYRA… Series
The LP471PYRA… probes consist of a pyranometer LPPYRA03, LPPYRA02 or LPPYRA10 equipped with the SICRAM module and a 5m or 10m cable for the connection of the pyranometer to the instruments HD31, DO9847, HD2102.2, HD2102.1 and HD2302.0, so to get the reading in W/m² directly on the instrument’s display.
-
product
Spring Contact Probes
Spring Contact Probes - Test Center: 50 - 100 milsCurrent Rating: 3 - 5 ampsContact Resistance: 30 - 50 milliohmsSpring Force: 113 - 312 gf (4-11 oz)
-
product
60 V Common Mode Differential Probes
The 60 V Common Mode Differential Probes are the ideal probes for lower voltage GaN power conversion measurement with the highest accuracy, best CMRR, and lowest noise.
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
Measuring Probes and Instruments for Meteorology
In meteorology, precise and reliable measurement data are critical for the preparation of accurate weather forecasts; as well as monitoring external conditions for integration with the building environmental systems.
-
product
Threaded Step Probes
Pin position sensing - adjustable height - custom designs - anti-jump solution.
-
product
MEP General Purpose Probes
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
product
Serial Probes
Probing a SRIO 1 or 2 serial bus at the transmit or receive end point provides the optimal signal for analysis. Single channel probes are designed to attach at that point providing flexibility for different channel widths.
-
product
BPLT-25 Long Travel Bead Probes
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cyles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
DDR4 MSO Probes
The DDR4 DIIM and SO-DIMM Mixed Signal Interposers connect Address, Command and Control signals of a DDR4 bus to the Keysight V-Series Oscilloscopes with the MSO option. These interposers also provide accessibility to DDR4 signals for convenient analog probing. The user can then easily observe both the digital and analog representation of the DDR4 Address, Command and Control bus. Solder down N5541A analog probes purchased separately from Keysight Technologies.
-
product
Manual Fixture Kit With Changeable Cassette, Max number of probes (2N) 1000 units, Max UUT 335 x 250 mm (wxd)
CMK-02
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
Energy Probes
RjP-400 Series
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Near Field Probes
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
product
High Impedance Active Probes
18C & 19C
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
product
Accessories, Styli & Probes
Pratt & Whitney Measurement Systems, Inc.
A Standard to Grow With
-
product
Power Rail Probes
Optimized for power integrity measurements, these probes combine low noise contribution, DC offset up to 60 V, high bandwidth, low loading, and a wide range of connectivity alternatives.
-
product
High Frequency Coaxial Analytical Probes
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
product
Probes, Clamp-On
EM-6981 | 9 KHz – 110 MHz
Current probes enable you to measure conducted current without direct connection to the circuit under test by clamping around the conductor, current carrying wire or structural member being tested.
-
product
RMP Replaceable General Purpose Probes
Current Rating (Amps): 2Average Probe Resistance (mOhm): 125Test Center (mil): 20Test Center (mm): 0.51Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 52Recommended Travel (mm): 1.33Mechanical Life (no of cyles): 50,000Overall Length (mil): 598Overall Length (mm): 15.19
-
product
Coupled Multielectrode Array Sensor (CMAS) Probes
CMAS probes are made from user-specified sensing materials, including carbon steels, stainless steels, and nickel-, aluminum-, and copper-based alloys. They can also be made from customer supplied materials that have the same microstructure/heat treatment as the system component materials to be monitored. The size of the sensing electrode varies from 0.1 to 3 mm (0.004" to 0.12") in diameter, depending on the application. Typical numbers of electrodes in a CMAS probe are 9, 16 or 25 for online corrosion monitoring and vary from 8 to 100 for laboratory corrosion and electrochemical studies.
-
product
ICT Probes
Merica Series-MPA75