Signal Conditioning
The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners
-
product
16-Channel VME Analog/Thermocouple Input Module
V450
The V450 is a 16-channel 24-bit VME isolated analog-to-digital converter module which can acquire a wide range of DC voltages, including thermocouple readings with automatic cold junction compensation. Each channel is independently isolated with it's own A/D converter, signal conditioning, input protection circuits, and test relay.
-
product
PCI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device
779111-01
32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
High Temperature Charge Mode Accelerometers
Charge mode output accelerometers from PCB® use piezo-ceramic sensing elements that output an electrostatic charge signal proportional to the applied acceleration. These sensors can operate at extremely high temperatures because they do not contain the built-in signal conditioning electronics that limit the temperature range of ICP® accelerometers. Charge mode sensors are used in the testing of gas and steam turbines, jet engines, high power motors, exhaust systems and automobile engines where temperatures can range from 500° F (260° C) to 1200° F (649° C).
-
product
2- to 8-Channel Anti-Alias Low-Pass Filter and Instrumentation Amplifier Card
AAF-3PCI
The AAF-3PCI is a 2- to 8-channel anti-alias low-pass filter and instrumentation amplifier PCI bus plug-in board for front-end signal conditioning in PC-based data acquisition systems.
-
product
PXI-6254, 32 AI (16-Bit, 1 MS/s), 48 DIO, PXI Multifunction I/O Module
779118-01
The PXI-6254 offers analog input, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
RTM Communication Board
MS 3636I
CPCI Rear IO Communication Board is a signal conditioning and interface board for CPCI Integrated Communication Card (MS3635i). This board has required signal conditioning and interface circuits for RS422. Two 96 Pin Euro Connectors are used to interface all IO’s.
-
product
15-CH Isolated Digital Output Module
ND-6056
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Dual-Axis Accelerometer For HS5 & 6 Handyscopes, +/- 2G
TP-ACC20-09
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 2G.
-
product
Boundary-Scan Controller for PXI-Express 'Hybrid' Slots or Plug-In Controller for PXI-Express Peripheral Slot
JT 37×7/PXIE
High speed and performance JTAG Boundary-scan controller for PXI-Express ‘hybrid’ slots or plug-in controller for PXI-Express peripheral slot.The controllers are targeted at demanding manufacturing test applications, fast in-system flash memory programming and programmable logic configuration. The JT 37×7 is available in different operating levels (memory options) to suit your specific environment and application. Each unit is supplied with a four TAP port signal conditioning module the JT 2147 ‘QuadPOD‘The JT 37×7 DataBlasters are a family of high speed and performance, up to 40 MHz TCK, boundary-scan controllers. Besides being available as bench-top unit with USB/E-net/FireWire interface, these controllers also come as 19″ rack-mountable instrument with the same three interafces and as plug-in cards in PXI(e)and PCI(e) formats.
-
product
SLSC and CRIO Modules and Accessories
Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.
-
product
In-Line IR Sensor
ILA
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
product
Signal Conditioning
Sensors that are used to collect the data from the environment often don’t produce signal of characteristics optimal for an analog to digital converter (ADC) to translate to digital data. Additionally, these signals can be subject to electromagnetic interference (EMI) that introduces noise, having a negative impact on the reliability of the data. To make this analog input readable for the processing unit and dependable enough to give the desired quality of data the signal has to undergo a process of signal conditioning.
-
product
Signal Conditioning
To get most out of high-quality sensors, accurate, low-noise processing of the sensor signals that are emitted is essential. Kistler offers an attractive portfolio of solutions for signal processing and subsequent data digitization. Piezoelectric (PE) sensors with a charge output require a so-called charge amplifier. On the other hand, piezoelectric sensors with integrated electronics (IEPE) are supplied by Piezotron couplers which decouple and amplify the signal.
-
product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
product
Coaxial Transfer Switch, DC to 50 GHz
87222E
Flexibility is essential in signal routing applications, and the Keysight 87222E 4-port coaxial transfer switch offers just that. It provides exceptional repeatability, low insertion loss, and high isolation. These switches provide simplification of design in signal routing and conditioning applications. The Keysight 87222E can be used in a variety of applications such as, a drop-out switch, switching two inputs and two outputs, or signal reversal switching.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
Crosspoint Switches
Macom Technology Solutions Holdings Inc.
At MACOM we offer the industry’s largest portfolio of low latency crosspoint switch devices with channel counts ranging from 2x2 all the way up to 288x288, and data rates from 3.2 Gbps to 28 Gbps. Our devices are equipped with signal conditioning technology that enables system designers to use lower cost board materials and components while increasing their system margin.
-
product
Multi-Channel Attenuation Control Unit (4-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7204A
The J7204A is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204A reduces cost of ownership and provide the best measurement accuracy.
-
product
3-Slot Data Acquisition Mainframe With GPIB And Three 20-Channel Multiplexer Modules
DAQ973MB
The DAQ973MB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
product
Ruggedized Ethernet Data Acquisition Systems
Series 7000
The Series 7000 Ruggedized Ethernet DAS brings new capabilities and levels of performance to transducer data acquisition. The ruggedized system is designed for installation in wind tunnels, engine test stands and other facilities where it is desired to locate the DAS on or near the test article, reducing installation and cable costs while improving signal quality and reliability. Each unit is a network appliance which conditions, amplifies and digitizes outputs from transducers. Multiple units are easily combined and distributable for larger installations. Real-time temperature Compensation of gain offset and Excitation Voltage, quality signal conditioning with high gain and a 24-Bit A/D per channel provide a high accuracy and high resolution DAS that will perform across a wide operating range.
-
product
Servo-Pneumatic Asphalt Testing System
All signal conditioning, as well as high-speed data acquisition and control functions are done by the unit and graphically interfaced through CATS, windows based software running on a standard PC. The system is capable of performing the full spectrum of HMA tests: dynamic complex modulus, flow number, flow time, indirect tension, beam flexural fatigue and resilient modulus. These tests are done with the appropriate testing modules. The different testing modules can be obtained after the initial system acquisition at the same discounted price. In addition, guarantees system upgrades in order to meet future standards .
-
product
Axial Extensometer
Model 3542
Jinan Testing Equipment IE Corporation
These extensometers are designed for testing a wide range of materials, including metals, plastics, composites and ceramics. All will work in both tension and compression. The dual flexure design makes them very rugged and insensitive to vibrations, which permits higher frequency operation.They come standard with Epsilon’s quick attach kit, making it possible to mount the extensometer on the test specimen quickly and easily with one hand. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The Model 3542 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.For gauge lengths 100 mm (4 inches) or greater see Model 3542L.
-
product
2 to 8 Channel Anti-Alias Low-Pass Filter Card
AAF-1
The AAF-1 is a multi-channel anti-alias low-pass filter board designed for front-end signal conditioning in PC-based or stand-alone 12-bit A/D conversion systems.
-
product
16-Channel Anti-Alias Low-Pass Filter Card
AAF-16
The AAF-16 is a 16-channel anti-alias low-pass filter card series for front-end signal conditioning in PC-based data acquisition systems.
-
product
Phase Meter
SD1000
The SD1000 phase meter offers superb accuracy with a wide range of signal conditions. Conventional phase meters are easily upset when small levels of noise and distortion are present - the result is often unstable and incorrect phase readings. The SD1000 overcomes this by using Discrete Fourier Analysis (DFT), this process rejects any noise and distortion without the need for tracking filters.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Power Quality Analyzer
PQM-703
Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.
-
product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.





























