Electrodes
-
Product
Electrodes
-
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
Product
Electrodes Sensor
6013
-
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
Product
High-Temperature and High-PressurepH Electrodes
UltraDeg
-
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
-
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
pH Electrodes
-
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
Product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
-
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
Product
Rebar
-
Continuously monitors the coating line process as reinforcing bar runs through the RBRS dual-roller wet sponge electrodes unit. When a holiday is discovered, a red light flashes at the appropriate station on the detector unit for a visual indication, and the unit sends an eletrical output to a plug on the back of the unit. The MSRB signal output plugs drive any 120 Volt AC customer furnished horn, bell, recorder or computer.
-
Product
Long Term Test Kit
-
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
Product
Handheld Water Quality Meters
LAQUA EC210
-
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
Product
Parallel Plate Dielectric Test Cell
LT-4203A
-
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
Product
Panel Mounting Conductivity Transmitter
DO9786T-R1
-
output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.
-
Product
Grid Electrode
-
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
Product
DryLoc pH/ORP Preamplifier and Connectors
2760
-
The 2760 preamplifier allows any DryLoc pH/ORP electrode to work with Signet ProcessPro and ProPoint pH/ORP instruments. It is also sold as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal.
-
Product
Premium Conductive Rubber Electrode
PRS-801-WV
-
- Ideal when qualifying or cerftifying material & installation- Each electrode has a resistance of less than 10 ohms- Flatness is measured and delivered within Prostat's specs- Capped to protect the pad against deformation- In accordance with ANSI/ESD S4.1 amd ANSI/ESD S7.1- NIST traceable ceritificate provided for each premium electrode
-
Product
Electrocardiogram Logger Sensor
NUL-218
-
Identical in its use to a regular medical ECG (electrocardiogram), this is a rather simple three lead based logger sensor. It presents a heartbeat graph that allows a thorough examination of the heart's electrical activity from three different angles. Unlike most ECG devices, this unit operates with non-disposable electrodes.
-
Product
Software to Simulate Large Area Semiconductor Devices
Laoss
-
Laoss is a powerful software to simulate large area semiconductor devices (OLED, thin-film PV), taking into account the voltage drop in the electrodes due to important resistive effects when the size of the device increases.Simulation of large area semiconductor devices (OLED, thin-film PV)Coupling law input: analytical or tabulated (experimental or simulated) IV curveDevice optimization (electrode material, device geometry etc...)High speed computation
-
Product
Earth Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Earth Ground Testing. Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
Product
Dielectric/Conductivity Sensor
Micro-VariconTM
-
The Micro-Varicon sensor is a miniature, thin, flexible dielectric sensor designedfor cost-sensitive use where space is limited. The electrode array is patterned on apolyimide substrate, and the Micro-Varicon sensor can be supplied with or withoutTeflon insulated leads.
-
Product
Bottom Electrode SMD Test Fixture
16198A
Test Fixture
Designed for impedance evaluations of bottom electrode SMDs and supports 201 (mm) and 402 (mm) sizes
-
Product
Cell Stand
CS-3A
-
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
Product
Portable Conductivity/TDS Meter with Conductivity electrode
CyberScan CON 11
-
User Customizable Functions for options: Normalization Temperature, Temperature Coefficient, TDS (Total Dissolved Solids) factor, Cell constant and many more
-
Product
Wood Moisture Meter
-
Using the principle of electrical resistance, pin-type meters use the board as an element in a circuit by driving two pins or electrodes into it. This method works because moisture conducts electricity well and dry wood is an effective insulator.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
Bench Meters
-
Both CyberScan Economy and Deluxe Bench Meters feature custom dual-display LCD for optimised data viewing, convenient detachable electrode stand, built-in memory, quick reference slide-out instruction card, HOLD function and other intelligent features.
-
Product
Syscal Pro switch
-
The Syscal Pro is an all-in-one multinode resistivity and induce polarization imaging system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250W, 2000Vpp internal transmitter which make it the more powerful system of the Syscal range. This system allows to perform up to 10 measurements at a time and its switching board allow to work for 48 (Switch-48) up to 120 (Switch-120) electrodes.
-
Product
Earth Resistance Clamp Meters
-
Precision Mastech Enterprises Co.
Specialized, non-intrusive electrical testing tools designed to measure grounding system resistance without disconnecting the ground rod or using auxiliary electrodes.
-
Product
Multi-probe for Ammonium and/or Nitrate
S470
-
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196A
Test Fixture
The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
pH 2700 Benchtop Meters
-
Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring.
-
Product
Soil Moisture Sensor
SoilWatch10
-
SoilWatch 10 is a soil moisture sensor which allows measuring relative water content in the soil. Our sensor does not have any exposed electrodes that usually corrode in resistive sensors. Whats more the reads will almost not drift over time or with temperature changes. Our sensor will give the same readings regardless of supply voltage. The sensor is weatherproof. It can be buried in soil for extended periods of time without adverse effects on accuracy or reliability. Designed to work with Arduino.