Electrodes
-
Product
Starter Electrodes
-
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
Product
High-Temperature and High-PressurepH Electrodes
UltraDeg
-
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
Product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
-
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
Product
Water Analysis Meters & Electrodes
-
Ideal for Accurate Everyday Measurements in the Laboratory
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
ESD LCD SURFACE RESISTIVITY METER (WITH 1 PAIR OF 5 POUND ELECTRODES)
-
The ESD LCD SURFACE RESISTIVITY METER provides everything necessary to test work surfaces using the procedure outlined in the EOS/ESD-S4.1 standard. This test kit makes testing surface resistance easy – simply place the weights attach the cables, switch to the correct voltage and press the button to read resistance directly on the meter. The meter incorporates parallel probes on the bottom of the unit which allows the user to make surface resistivity measurements. The parallel probes allow for quick and easy testing of a variety of surfaces and materials, without the use of the five pound electrodes
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
-
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
Counter Electrodes
-
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
Product
Working Electrodes for Flow Cell
-
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
-
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
Product
Electrodes
-
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
-
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
Product
Radial Flow Cell
-
The wall jet of the sample, after hit in to the surface of the electrode, spreads in three dimensions. After hitting the sample on a thin layer electrode directly, it flows to the perimeter from the center of the radiated electrode, improving the sensitivity.
-
Product
Wood Moisture Meter
-
Using the principle of electrical resistance, pin-type meters use the board as an element in a circuit by driving two pins or electrodes into it. This method works because moisture conducts electricity well and dry wood is an effective insulator.
-
Product
Electrodes
-
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
Product
ICP Plasma System
-
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
Product
High Speed Spectroscopy Camera
SynapsePlus CCD
-
Superfast electronics (up to thousands of spectra per second). Very low read noise. Best linearity in its class. Different chip types to suit every spectroscopy need. Open Electrode (OE) 1024 x 256 pixels, Front-illuminated UV enhanced (FIUV) - 2048 x 512 pixels, Front-illuminated visible (FIVS) - 2048 x 512 pixels, Back-illuminated UV enhanced (BIUV) - 1024 x 256 and 2048 x 512 pixels, Back-illuminated visible (BIVS) - 1024 x 256 and 2048 x 512 pixels, Back-illuminated deep depletion (BIDD) – 1024 x 256 pixels.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
Liquid Test Fixture
16452A
-
The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.
-
Product
Semiconductor Packaging System
-
Inspects the quality of finished cells by measuring the gap between the battery electrode laminate and aluminum can.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
pH 550 Benchtop pH Meter Kit with Probe, Stand, and pH Buffers
-
The PH 550 benchtop pH meter features a microprocessor chip which provides automatic temperature compensation, data storage, parameter setup, and Max/Min reading display. The meter offers a pH range from 0 to 14 and a three-point automatic calibration, with the ability to recognize standard buffer solutions (USA or NIST series). The advanced digital processing technology improves meter response time and measuring accuracy. A stable reading display icon appears when the measuring value is stable. The 3-in-1 combination pH electrode measures pH and temperature simultaneously. The compact meter includes a detachable electrode holder and three bottles of pH buffer solution. It has a dustproof and spillproof rating of IP54. Connectors are protected by silicone seal caps.
-
Product
Meter With Self-Stirring Dissolved Oxygen/BOD/ATC Electrode
DO 2700
-
Designed for optimal performance and versatility, the DO 2700 come with intuitive, advance set-up options for extensive user-customization at an affordable price! Meter comes with self-stirring probe and bi-directional RS232 – ideal for BOD and other Dissolved Oxygen applications in the laboratory.
-
Product
Waterproof Handheld Meter with pH electrode
CyberScan PCD 650
-
A Eutech Star Buy! Combining the strengths of all CyberScan 600 series meters, the CyberScan PCD650 is our top-of-the-line waterproof handheld that enables concurrent measurement of pH, conductivity, dissolved oxygen and temperature, all at the same time.
-
Product
Scanning Vibrating Electrode Technique
VS-SVET
-
The Scanning Vibrating Electrode Technique uses a single wire to measures voltage drop in solution. This voltage drop is a result of local current at the surface of a sample. Measuring this voltage in solution images the current at the sample surface. Current can be naturally occurring from a corrosion or biological process, or the current can be externally controlled using a galvanostat.
-
Product
Parallel Electrode SMD Test Fixture
16192A
-
The 16192A test fixture is designed for impedance evaluations of side electrode SMD components. The minimum SMD size that this fixture is adapted to evaluate is 1(L)[mm].
-
Product
Electrochemical Analyzer
EC Epsilon EClipse
-
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.





























