Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1E
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard In-door Forward Optical Receiver
HR8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
HR8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Electrical Calibration
-
We offer electrical calibration on a wide range of instruments covering all brands and types of electrical testers. Being the only calibration company in Ireland to have Fluke's state of the art 5320a Multi-product calibrators allows us to match or in many cases exceed the manufactures calibration such as Fluke, Megger, Kewtech etc, but for a lot less cost and downtime to you.
-
Product
Dry Block Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
Dry Block calibrators are used for the most accurate calibration of temperature devices. Ideal for quick / fast Site Calibration of RTDs / Bi Metal Thermometers, Temperature Switches / Indicators etc. in Industrial & Marine Applications. Dry block calibrators can be used for a very wide range of temperature from – 100°C to over 1500°C. Nagman hosts a range of calibrators that are Stable, portable, heavy duty and budget friendly.
-
Product
Calibration Measurement
-
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
Standard IR Target Projectors
-
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Multiport Calibrated Measurements With Switch Instruments
S97553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments
-
Product
Standard Clamp-On Ultrasonic Transmitter
KATflow 100
-
The KATflow 100 is a compact clamp-on ultrasonic flow transmitter with a robust and practical design for permanent installation and flow measurement on single pipes.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1UN-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Calibration
-
Get the precision calibration tools you need to maintain the accuracy of your process, electrical, temperature, pressure, and flow measuring instruments and equipment. In addition, our in-house metrology lab will precalibrate an instrument at time of order or recalibrate equipment already owned. Our NIST-traceable calibration services and repairs help you meet your quality, regulatory, and compliance needs.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
NF-Series Standard Models
-
The E-DRIV® NF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Energy Meter Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
The process of verifying the measurement accuracy and working status of the energy meter through the actual test.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1A-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Gain Horn Antenna
KSHA-BJ260-25-2.92L
-
Standard Gain Horn Antenna, Frequency21.7~33GHz, Gain 25dBi, Linear Polarization, 2.92-Female
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1R1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Temperature Calibrators
-
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
Product
Dimensional Calibration
-
Process Instruments certifies Gage Blocks with a state-of-the-art Pratt & Whitney Gage Block Comparator. Outside and Inside Micrometers, Depth Micrometers, Height Gages, Calipers and Dial Indicators can be repaired and calibrated to manufacturers'' specs.
-
Product
Standard Voltage 78 Pin D-Type Cables - Calibration Cables For Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 78-pin D-type calibration port connector.
-
Product
Calibration Tool
Software
-
The smartGAS Calibration Tool is a commercial software company that makes it possible to interact with all smartGAS sensors of the EVO series with firmware version 5.17 or higher. With the smartGAS Calibration Tool, it can be read out and the zero point and the end point can be used with a suitable test gas.
-
Product
Cryogenic Millimeter-Wave / Microwave Test Fixtures and Calibration Kits
upj10
-
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.





























