Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-V
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard Modal Analysis
-
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Calibration
Field Probes
-
We calibrate following types of field probes:Electric field probesMagnetic field probesFlux density metersRadiation monitorsNear field probes
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I8-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Phase Angle Voltmeter, Industry Standard
2250A
Phase Angle Voltmeter
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3F
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Balanced and UFL Calibration Kit
CAL-UFL-BAL
-
The Balanced Calibration Kit is an interface kit for UFL and balanced VNA measurements. It contains SMA-UFL adapters and several adapters from SMA and UFL to balanced pinheaders. The UFL connector was introduced by Hirose as the U.FL connector and became very popular for connecting RF signals in consumer electronics. There are several varieties from other manufacturors and are also known as UMC or UMCC connectors.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Standard Patchcords
-
VPC's standard and stocked patchcords make patchcord order and delivery quick and easy. Available in signal (QuadraPaddle and TriPaddle), power and coax.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
SIM, Module, Receiver, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510170102
Receiver Module
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
Product
CMOS Standard Image Sensors
-
The vision market is constantly looking for highly specialised, cost effective solutions where performance is not compromised. Teledyne e2v has over 40 years of heritage in imaging, with a background in the design and manufacture of CCD and CMOS image sensors.Capabilities include ultra-high speed and ultra-low noise. Teledyne e2v’s unique approach involves listening to the market/application challenges of customers and partnering with them to provide an innovative solution which brings real value to their systems.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62T1-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T75
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
The Gold Standard for Breast Screening & Biopsy Training
Mammography QA Solutions
-
When the USA mandated Mammography QA requirements via the Mammography Quality Standards Act (MQSA), medical physicists, the ACR and the FDA worked with Gammex to complete the phantom design known today as the 156 Phantom.
-
Product
Helmholtz Coils (Field Standards)
-
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
Product
Calibration Equipment
-
Calibration is the method of comparing tools and measuring devices to higher accuracy standards. Torque calibration equipment is the official means by which torque testers and sensors are calibrated and are traceable to National or International Standards, such as N.I.S.T and ISO. In order to maintain precision accuracy, it is essential that torque measuring equipment be calibrated regularly. By equipping your team with Mountz calibration equipment, you can avoid the costly chore of sending your torque tools to the lab whenever they fall out of alignment.
-
Product
GPS Frequency Standards
-
Precision Test Systems manufacturers' a full range of GPS and GNSS frequency standards that are disciplined to most of the worlds satellite systems.
-
Product
Turbidity And Standard Meters
-
Accurately measure the cloudiness of a fluid caused by suspended particles with turbidity meters and standards from HF scientific. Our turbidity meters and standards instruments include features that simplify installation, maintenance, and data access.We offer reliable turbidity meters including an online turbidity meter, handheld turbidity meter, and benchtop turbidity meter.