Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Voltage 9 Pin D-Type Connector Blocks for Pickering Products
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L18-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-3W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Standard Lifetime Measurement System
Filter-Based Systems
-
*Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules
-
Product
Digital & ARINC Standards Display Panel
TA-3001
-
This is our soon to be introduced Digital Standards Panel. (2ND QTR) This panel is available with or without a Precision Resolver drive. Included on the panel are four digital displays; TA-902 API, TA903-01 OBI, TA903-02 Distance and a TA903-03 serial distance display. This panel when paired with the TA-3000 GPS/FMS test panel will make one of the most capable testing solutions available today
-
Product
Service, Modernization, and Calibration Serivices
-
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
Product
Calibration Services
-
Hirst Magnetic Instruments Ltd
Calibration is essential to keeping our sensitive measuring equipment accurate. We calibrate equipment traceable to National Physical Laboratory (NPL) standards.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Disciplined Frequency Standard
2975AR
-
The 2975AR contains a rubidium timebase and provide one 10 MHz, one 5 MHz and one Signal Generator output. The Signal Generator uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50 MHz using front panel controls or from an RS232 serial interface. The 2975AR can be disciplined by a 1pps input signal and provides a 1pps output signal. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
Product
Viscosity Standards
-
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Acoustic Calibrator
CAL150
-
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
Product
Standards Waveform Generator
3110A
-
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50U
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Single Or Dual Stream MIL-STD-1553A/BTest And Simulation Module For Standard Ethernet
ANET1553-x
-
The ANET1553-x is a member of AIM’s new line of Ethernet based modules for analysing, simulating, monitoring and testing MIL-STD-1553A/B databuses. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-6
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
ITO Sheet Resistance Standards (ITOSRS)
-
Indium Tin Oxide Sheet Resistance Standards (ITOSRS) from VLSI Standards are NIST-traceable products, intended for calibration of both contact and non-contact sheet resistance measurement tools used in the LCD, flat panel and touch-screen markets.
-
Product
Working Standard Shunts
CSW
-
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard DUO
-
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.2 axis design for rotary tilting applications with self-locking worm gearing and a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
NIST Calibration for D400A-AT
D400A-AT-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead





























