Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Portable Calibration Baths
6109A / 7109A
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Calibration Management Software
MET/CAL®
MET/CAL software is structured around the flow of instruments through the calibration process and addresses a wide range of test and measurement instrument calibration needs, from the simple to the complex. It is based on the traditional calibration model as its framework—comparing an instrument to a standard of known uncertainty.
-
product
Calibration
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
product
Decade Resistance Substituter Lab Standard
HARS-LX Series
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
product
450MM 18In Digital Level Bevel Gauge w/ LCD Backlight Screen, Magnets, Level Bubbles, IP54 Standards
DL400
Advance Plus Trading Co., Ltd.
Model Number: DL400 Key Specifications/Special Features: 450MM 17.7INCH Digital Level with level bubbles, strong magnets,LCD bright backlight display, IP54 standards 1. 450mm 17.7 inch level with 2 bubbles, 450*28*64mm(L*W*H), net weight: 430g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. With strong magnets in the bottom;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
product
Gauges & Calibrators
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard Voltage 37 Pin D-Type Connector Blocks
The connector blocks and breakouts below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
Standard Step Tablets, Gray Scales & Density Reference Charts
Standard Step Tablets, Gray Scales & Density Reference Charts are available in a wide variety of patterns, designs and sizes to fit a multitude of today’s application needs. Our gray scales and density patches are measured on a variety of NIST traceable instrumentation, including some of the most sophisticated microdensitometers available to the industry. They are imaged on either Photo Paper (RM) or Film (TM) to function for reflective or transmissive applications.
-
product
Coating thickness XRF Standards
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4-S
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL D
The 72-7755 CAL D from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-3
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
NIST Calibration for D400A-AT
D400A-AT-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Xytronic Three-Phase Site Analyzing Standard
RADIAN RX-3X-A
The RX-3X-A Xytronic Three-Phase Site Analyzing Standard brings precision measurements, normally associated with laboratories, to the meter site at a surprisingly affordable price. How is this possible? Radian has always designed state of the art precision measurement equipment with extreme high and low operating temperatures in mind – all site analyzers are tested at -20C to +70C. Couple precision measurement with ruggedness, throw PCSuite software automation into the mix, you have the premier RX Site Analyzing solution to meet the most demanding site measurement challenges
-
product
NanoCD Standards (NCD)
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
product
Bench Power Supply, Calibrated w/D & U, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL DU
The 72-2690 CAL DU from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
product
Photometric Ozone Calibrator
Model T703
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
product
Standard Type
FD-10
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
product
Calibration
The Young Calibration laboratory provides UKAS calibration (Laboratory 0604) services and testing to all industries whilst maintaining a reputation for quality, cost effectiveness and reliability.Water Flow Calibration, Oil Flow Calibration, Air Velocity Calibration, Humidity Calibration, Pressure Calibration, Temperature Calibration, Electrical Calibration, Mechanical Calibration, Automotive Calibration, Medical Calibration, On-Site Calibration,
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1P1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
product
Standard Voltage 37-Pin D-Type Connector & Cable Accessories
The Standard Voltage 37-Pin D-Type connector is used on PXI switching products to provide a medium density connector solution.Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
product
Digital Load Calibrator
HS 2000
Jinan Testing Equipment IE Corporation
The load cell calibrator is used to calibrate the load of testing machine and hardness tester, and also can be used for force measuring. It is digital display type with high accuracy of less than +0.3%, and easy to operate