Contacts
See Also: Modules, Wire, Connectors, Patchcords, Flying Leads
-
product
PCI Express 16 Reed Relay Output Digital Interface
8003e
The 8003e PCI Express digital I/O interface provides 16 Reed relay outputs. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications up to 10VA. Reed relays are normally open and close when energized. The board is PCI Express X1 compliant and is compatible with any PCI Express slot.
-
product
Laser Head
5517C
The Keysight 5517C is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Option 009 allows a larger angular range of measurement by providing a 9 mm beam diameter for use with three-axis interferometers. Please contact Keysight for custom requirements.
-
product
Junior Set and Kits
Contents* AM-510-EUR (Digital multimeter)* ACD-10 PLUS (Digital current clamp)* TPP1-C1 (contact thermometer)* EU-200 (test lead set with 2 leads), 2 test prods (4 mm), 2 crocodile clips (CAT III/1000 V)* Hard carrying case
-
product
Linear Actuators
Electrak 100
Thomson continues its strong support of our current customers through our legacy product families. We encourage our customers to contact our sales application teams to discuss new and improved product offerings. See the table below for our recommended replacement for the Electrak 100 legacy actuator.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
Micro Coax, Contact, ITA, 75 Ohm, RG179
610141103
Primary mating contact 610140103. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 75ΩFrequency Range DC – 2 GHzVSWR 1.39 @ 2 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG179Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Latching / Bistable Heavy Duty Power Relays
The voltage pulse will activate the relay to pull-in or release the contacts. The latching relay / bistable relay will hold its contactposition till the next voltage pulse. Below latching relays / bistable relays are designed for demanding heavy duty applications.
-
product
Solid State Relays
As well as being slim and thus saving panel space, The relays are very strong, have a large contact area and non-bendable pins. Connection to a PLC is easy and achieved faultlessly in a few seconds via click connectors. In addition, power switching in G3RV relays with DC outputs is managed by a MOSFET in the output, which has ideal heat dissipation characteristics.
-
product
Signal, Contact, Receiver, TriPaddle, 7 Amp, 20-24 AWG, Crimp only
610110101
Primary mating contact 610110108. (May mate with other ITA contacts, as well.)p/n 610110125 TriPaddle Receiver 50µ" AU plating.p/n 610110101 TriPaddle Receiver 30µ" AU plating.Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination CrimpCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
Primary & Secondary Current Injection Testing Sets
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
product
D1 Series
With VPC's most compact design, the D1 is compatible with a variety of hybrid I/O modules that include: power, coax, signal, vacuum, pneumatic, and high speed digital. Despite its compact size, the D1 can engage up to 160 signal contacts simultaneously.
-
product
NON CONTACT DIGITAL THERMOMETER
IBL-MT6
International Biological Laboratories
This Digital Non Contact type Infra Red Thermometer with laser sensor uses temperature sensor of Thermopile 6 - 14 mm with laser specifications wavelength of 650microm to measure temperature from -20 to 550 Degree C and also in Fahrenheit scale
-
product
Digital Paper Moisture Content Meter
Model KM 963-P(N)
Kusam Electrical Industries Limited
Digital intelligent MCU Paper Moisture Meter works on 3 types of paper (Writing paper, Copper-print (Art) paper, Newsprint paper) by using the spring contact for precise measuring.
-
product
Temperature Meters
PCE Instruments’ temperature meter products are precise, portable, handheld devices ideal for professional, industrial, commercial and residential use. From contact temperature meter devices with probes to noncontact temperature meter devices using infrared or laser technology to measure temperature from a distance, PCE Instruments offers a wide range of accurate, reliable temperature meter products at an affordable price.Temperature is measured and recorded in many different applications. For example, HVAC technicians measure temperature to identify and address issues in heating or cooling systems, while quality control professionals in the food sector measure temperature to ensure the proper storage and preparation of everything from meat and produce to cheese and frozen foods. PCE Instruments carries a variety of temperature meter products, including temperature meter devices to measure different temperature ranges between -200 and 1767ºC / -328 ... 3212ºF; temperature meter devices that can indicate temperature in °C (Celsius), °K (Kelvin) and °F (Fahrenheit); and temperature meter devices that are water resistant. In addition, a number of thermal elements and type-K sensors are available for different temperature meter products.Each temperature meter comes factory calibrated to ensure accurate measurement. ISO-certified calibration, performed by one of our first-class calibration laboratory partners, may be obtained on most temperature meter models for an additional fee.A temperature meter is an instrument used to measure the temperature of beings or things. The most widely recognized temperature meter is a mercury thermometer used to measure the temperature of people. These thermometers consist of a graduated glass capillary with a pool of mercury in one end. However, there are many different types of temperature meters, such as digital thermometers that take temperature measurements on contact with an object or infrared temperature meters that take measurements at distance, without contact.
-
product
Needle Microprobe
MT-29/2HT
Fast-response 29 gauge needle probe, (needle length is 2cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
PXI Dual 8 Channel Switch Simulator
40-485-121
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
product
Micro Power, Insert, ITA, SIM, 2 Pos, 2 Slot
510181102
This insert contains 2 micropower contacts and is part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module.
-
product
Chroma Milliohm Meters
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
product
Micro Power, Contact, Receiver, 21 Amp, 12-14 AWG
610142101
Primary mating contact 610143101. (May mate with other ITA contacts, as well.)Specifications Operating Current 21 amps continuousContact Resistance 1.5 mOhms max.Dielectric Withstanding Voltage (DWV) 1500 VDC min.Contact Body BrassContact Plating 30µ" Au over 100µ" NiContact Termination CrimpCycle Life 10,000 cyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.23
-
product
Handheld Reflectometers And Emissometers
Are portable contact measurement devices designed to take precise, accurate measurements.
-
product
AC/DC Voltage Detector (CONTACT TYPE)
LVD-20
Standard Electric Works Co., Ltd
Contact type. LED indication and audible alarm sound when voltage is present. Designed for AC/DC voltage detection. Used for bare wires or conductors. Self-test function. For indoor use only. Low power consumption. Light weight and compact.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
Needle Microprobe
MT-D
Fast-response 29 gauge needle surface probe for locating inflammation, arteries, etc. Also for dental use. 1/4'' right angle needle length, 3/4'' needle distance from lead. 5.5'' long handle for ease of use. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Sensor within .3mm of tip. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
product
Geotextile Water Flow Capacity Tester
TG050
TESTEX Testing Equipment Systems Ltd.
The flow of water within the plane of a geotextile or geotextile-related product is measured under varying normal compressive stresses, with typical hydraulic gradients and with defined contact surfaces.
-
product
Solar Panel Probes
*Effective *Reliable solution for non-destructive electrical contacting *For standard or custom applications
-
product
Dynamometers For EV & Traction Motors
MOTOMEA’s extensive catalog puts years of innovation at your fingertips. While we invite you to browse online today, we also encourage you to contact us directly to source the specific products you need.
-
product
USB 3.0 Type A (With Shielding) Test Connector
Test connector for USB 3.0 Type A with shielding (9 pole) for contacting USB interfaces. Application in high-speed USB devices like hard disks, data carriers, power supplies, etc.





























